TSE adoption lookup for EN 50600-2-6 (unverified)
Türk Standardları Enstitüsü (TSE)
A lookup record for EN 50600-2-6 showing that the 2014 draft was later replaced by another part.
On this page
Overview
The only European document found for part 2-6 is the draft prEN 50600-2-6:2014. The DIN catalogue states explicitly that this draft was replaced by DIN EN 50600-3-1:2016-08, so no published EN 50600-2-6 appears to exist.
The record's core rule is that a published TS EN 50600-2-6 must not be inferred from the 2014 draft. TSE's programme (January-February 2024, printed page 8) names only the EN 50600-2-x series collectively, with no individual part number.
TSE document URL, adoption year, Turkish title, aligned European edition and translation-versus-English-endorsement status all remain unverified. The linked address is a catalogue search form rather than a single document, and a direct request hit a bot challenge.
Key points
- Only European document found: prEN 50600-2-6:2014, a historical draft.
- DIN record: the draft was replaced by DIN EN 50600-3-1:2016-08.
- A published TS EN 50600-2-6 cannot be inferred from the draft.
- TSE's individual TS number, title and adoption year are unverified.
- The published counterpart to look at is probably EN 50600-3-1, covered in its own record.
Using it in design
- If a reference list cites '2-6', check which published part is actually meant and compare it against 3-1.
- Do not use prEN drafts as a source of requirements.
Monthly newsletter · free
Keep your reading list current
Once a month: new library sources, changes to Turkish regulations and upcoming data centre events.
SoSo CAD
Assess redundancy through scenarios
Compare normal operation and equipment failures in SoSo CAD, with supplied loads and capacity shortfalls in one view.
Request a demo
Who should read it
Engineers who meet an EN 50600-2-6 citation in an older specification and need its valid counterpart.
Related standards
- EN 50600-2-6
Publication details
- Authors
- Türk Standardları Enstitüsü (TSE)
- Publisher
- Türk Standardları Enstitüsü (TSE)
- Year
- Year not stated
- Document language
- English
- Source type
- Standard
- Access
- Citation only
- Licence
- Copyright retained; citation only — the publisher’s terms apply to the original document
Original licence note
No permission to redistribute TSE standard texts is asserted. This record contains only bibliographic research metadata and official links; no standard text, excerpts or file.