PUE: A Comprehensive Examination of the Metric (ASHRAE Datacom Series Book 11, with The Green Grid)
ASHRAE / The Green Grid · ASHRAE TC 9.9, The Green Grid
A Datacom Series book from ASHRAE TC 9.9 and The Green Grid that consolidates PUE concepts, measurement and reporting.
This document is sold by ASHRAE / The Green Grid and is available from the publisher’s site. SoSo CAD does not sell or distribute it; this page holds only catalogue details and our own summary.
On this page
Overview
This work is Datacom Series Book 11 (product code 90282, 2014), a joint publication of ASHRAE TC 9.9 and The Green Grid. The book gathers the concepts, measurement, reporting and analysis of the PUE (Power Usage Effectiveness) metric in one place. PUE was developed by The Green Grid and first published in 2007; the book is positioned as a comprehensive reference that consolidates what has been issued since.
The scope goes beyond the basic PUE calculation. It covers partial PUE, mixed-use and specialised facilities, and the reuse of waste heat. This sheds light on how PUE should be interpreted not only in a single-purpose, single-tenant data centre but also in buildings shared with offices or other functions and in facilities that recover heat. The book supersedes and consolidates all earlier Green Grid PUE white papers, and its definitions are harmonised globally. It therefore serves as the definitive reference for users who meet inconsistent wording across different documents. Related standards include ISO/IEC 30134-2 and EN 50600-4-2.
Green Grid members can download it from the workspace for personal use at no charge, while other readers buy it from the ASHRAE bookstore. This record is based on catalogue and library-page descriptions rather than the book's content, so detailed method and limitations cannot be reported here; the book itself should be consulted for those.
Key points
- ASHRAE Datacom Series Book 11, product code 90282.
- PUE was developed by The Green Grid and first published in 2007.
- The book consolidates PUE concepts, measurement, reporting and analysis.
- It covers partial PUE, mixed-use and specialised facilities, and waste-heat reuse.
- It supersedes all earlier Green Grid PUE white papers and harmonises definitions globally.
- Green Grid members can download it free for personal use; others purchase it from the ASHRAE bookstore.
- Related standards: ISO/IEC 30134-2 and EN 50600-4-2.
Using it in design
- Define the measurement categories and the system boundary covered by partial PUE in the calculation.
- For mixed-use buildings, separate the data centre portion before calculating PUE.
- For facilities with waste-heat recovery, treat heat reuse following the approach in this reference.
- In PUE reports, state definitions and measurement points consistent with ISO/IEC 30134-2 and EN 50600-4-2.
Who should read it
Data centre engineers who calculate PUE, plan metering or report energy efficiency.
Related standards
- ISO/IEC 30134-2
- EN 50600-4-2
Publication details
- Authors
- ASHRAE TC 9.9; The Green Grid
- Publisher
- ASHRAE / The Green Grid
- Year
- 2014
- Document number
- Datacom Series Book 11 (product 90282)
- Document language
- English
- Source type
- Standard
- Access
- Paid; available from the publisher
- Licence
- Copyright retained; citation only: the publisher’s terms apply to the original document
Original licence note
Copyrighted ASHRAE book sold via ASHRAE Bookstore (and TC 9.9 Datacom Encyclopedia subscription). Not read; metadata from ASHRAE catalogue / Handbook descriptions only. Citation only.
Citation
ASHRAE TC 9.9; The Green Grid (2014). PUE: A Comprehensive Examination of the Metric (ASHRAE Datacom Series Book 11, with The Green Grid). ASHRAE / The Green Grid. Datacom Series Book 11 (product 90282). https://www.thegreengrid.org/en/resources/library-and-tools/20-PUE:-A-Comprehensive-Examination-of-the-Metric