Technical guideFree to readYear not stated

MN Series: Monobloc Centrifugal Pumps Based on DIN 24255

Original title MN Series: Monobloc Centrifugal Pumps Based DIN 24255

Bombas Azcue

Bombas Azcue's MN series of monobloc centrifugal pumps based on DIN 24255 dimensions, with 50 Hz (1450 and 2900 rpm) and 60 Hz (1750 and 3500 rpm) performance graphs and flange sizes DN 32-200.

On this page

Overview

The catalogue (ref. MN 05, MN-061) presents Bombas Azcue's DIN 24255-based monobloc centrifugal pump family. The pump code has the form 'MN - flange size - nominal impeller diameter' (for example MN 150-250). Standard material is cast iron GG25 or bronze (Rg5); bronze, G-CuAl10Ni and stainless steel (AISI-316) are alternatives. The shaft is AISI-316 stainless steel; wear rings can be bronze, cast iron or stainless steel.

The maker lists as advantages low NPSH, simple assembly without alignment, easy dismantling, interchangeability to DIN 24255, an IEC motor and a mechanical seal to DIN 24960. Performance graphs are given for two frequencies and two speed groups: 1450 and 2900 rpm at 50 Hz and 1750 and 3500 rpm at 60 Hz. The graphs cover sizes 32-125 up to 150-400 on flow (m3/h and gpm) and head (m and ft) axes.

The catalogue also gives tables of motor power (kW and HP), form and mass for each speed group, plus mechanical drawings; there are different drawing groups for flanges DN 65, 80, 100, 150 and DN 200. These tables are not a selected hydraulic duty; the design point must be read from the curves and the motor power chosen accordingly. The document has no selection example specific to a cooling-water or chilled-water circuit.

Key points

  1. DIN 24255-based monobloc centrifugal pump; code MN - flange - impeller diameter.
  2. Speed groups: 1450 and 2900 rpm at 50 Hz; 1750 and 3500 rpm at 60 Hz.
  3. Performance graphs cover sizes from 32-125 to 150-400.
  4. Material: cast iron GG25 or bronze (standard); bronze, G-CuAl10Ni or AISI-316 stainless options.
  5. Shaft AISI-316 stainless steel; wear rings bronze, cast iron or stainless.
  6. Advantages: low NPSH, alignment-free assembly, easy dismantling, IEC motor, DIN 24960 mechanical seal.
  7. Motor power and mass tables are separate per speed group; no selected duty.

Using it in design

  • Read the design flow and head point from the graph of the correct frequency and speed group; do not mix 50 Hz and 60 Hz.
  • When selecting, compare required NPSH with the circuit suction condition; the low-NPSH advantage can help.
  • For cooling water, glycol or corrosive liquid choose material (cast iron, bronze, AISI-316) and seal by the liquid.
  • Choose motor power from the table by the demand at the curve point plus margin; carry it into the electrical load and the variable-speed drive decision.
  • Use DIN 24255 interchangeability in pump-replacement projects for dimensions and flange change.

Who should read it

Mechanical designers selecting cooling-water and auxiliary circuit pumps and engineers on pump-replacement projects.

Document contents

  1. Nomenclature and materials
  2. Advantages
  3. Performance graphs 50 Hz (1450 and 2900 rpm)
  4. Performance graphs 60 Hz (1750 and 3500 rpm)
  5. Motor, form and mass tables
  6. Mechanical drawings

Publication details

Authors
Bombas Azcue
Publisher
Bombas Azcue
Year
Year not stated
Document number
MN 05 / MN-061
Document language
Unverified
Source type
Manufacturer
Access
Free to read
Licence
Copyright retained; citation only: the publisher’s terms apply to the original document
Original licence note

No document-specific redistribution permission was established. Bibliographic reference only.

Citation

Bombas Azcue MN Series: Monobloc Centrifugal Pumps Based DIN 24255. Bombas Azcue. MN 05 / MN-061. https://northridgepumps.com/upload/pdfs/Azcue-MN-Centrifugal-Pump-English.pdf

All content and rights belong to the respective authors and publishers. SoSo CAD provides only the citation, its own summary and a link to the source, and is not responsible for the sources' content.

Cooling capacity in SoSo CAD

Check zone heat loads, installed capacity and the capacity left with the largest unit out, as part of the design.

Zone heat loads and capacity balance in the SoSo CAD cooling workspace

Keep your reading list current

Once a month: new library sources, changes to Turkish regulations and upcoming data centre events.