Energy Efficient Dynamic Virtual Machine Allocation with CPU Usage Prediction in Cloud Datacenters
Bilkent University · Gökalp Urul
A 2018 Bilkent University M.Sc. thesis: in CloudSim simulation the LRAPS method cuts total energy by about 22 to 28% against threshold methods and about 10% against local regression (LR).
On this page
Overview
The thesis was written by Gökalp Urul in the Computer Engineering department of Bilkent University in January 2018. Its subject is reducing energy consumption in cloud data centres without breaking service-level agreements (SLAs). The proposed LRAPS (Local Regression Automated Parameter Selection) method predicts a host's short-term CPU utilization from its usage history and uses the prediction to trigger virtual-machine (VM) live migration.
On an overloaded host some VMs are moved elsewhere to avoid SLA violations; if an underloaded host's VMs can all be moved, the host is switched off. In local regression the span value strongly affects results: a small span overfits short spikes and raises false migration alarms. LRAPS selects it automatically by cross validation (GCV). Experiments ran in CloudSim with 300 heterogeneous hosts (HP ProLiant ML110 G4 and G5) and 500 VMs over 24-hour periods.
The data are PlanetLab traces (four different days), a randomly generated workload, Materna data-centre traces and Bitbrains traces. LRAPS is compared with static thresholds (THR 0.7 and 0.8), MAD, IQR and LR. SLA violation is measured with SLATAH (the share of time active hosts run at 100%), PDM (performance degradation due to migrations) and their product, SLAV.
The evidence is simulation and depends on a server power-curve model; it contains no measured facility PUE or cooling effect. The findings show how workload management changes IT-side energy. For a designer doing capacity planning, the value is in seeing how high-utilization and migration strategies change the per-server load profile and therefore the distribution of power and cooling load.
Key points
- LRAPS lowers total power consumption by about 23%, 28%, 25% and 22% against THR 0.8, THR 0.7, IQR and MAD, and by about 10% against the closest competitor, LR.
- SLA violation sits around 10% for all methods (random workload excepted); LRAPS is 4.8% to 7.6% lower than the others.
- VM migrations fall by about 31.7%, 36.2%, 32.4%, 32.2% and 27% against THR 0.8, THR 0.7, IQR, MAD and LR respectively.
- Static-threshold methods consume the most energy: THR 0.7 stops servers from exceeding 0.7 utilization, so more sleeping servers are woken.
- The setup is 300 hosts (half ML110 G4, half ML110 G5), 500 VMs and 24-hour runs, with minimum migration time as the VM selection policy.
- Datasets: PlanetLab (5-minute samples, 288 points per day), Materna (Dortmund, 49 hosts), Bitbrains (1,750 VMs) and a random 800-VM workload.
- On some datasets (Materna-2 energy and migrations, Bitbrains SLA) LRAPS is not the best; the gain depends on the workload.
- Results rest on simulation and a host power model and include no facility-wide PUE measurement.
Using it in design
- If IT load consolidation is planned, reflect in the capacity plan how powering off emptied hosts changes the power and cooling load profile.
- Compare placement policies that use short-term utilization prediction with static thresholds; a low static threshold means more active hosts and more energy.
- Track migration count as a cost: migrations add network and performance load and show up in SLA metrics.
- Assess energy-saving claims separately from facility PUE; this work shows IT-side savings based only on a host power model.
Who should read it
Teams running cloud and virtualization infrastructure, capacity planners and engineers studying the link between workload management and energy efficiency.
Document contents
- Introduction
- Background and related work (virtualization, VM migration, resource allocation)
- Proposed method: local regression, span selection and LRAPS
- Experiments and simulation results (CloudSim)
- Conclusion and future work
Publication details
- Authors
- Gökalp Urul
- Publisher
- Bilkent University
- Year
- 2018
- Document number
- M.Sc. thesis, Computer Engineering, January 2018
- Document language
- English
- Source type
- Scientific
- Access
- Free to read
- Licence
- Copyright retained; citation only: the publisher’s terms apply to the original document
Original licence note
Official publisher or university publicly accessible text; no open redistribution licence established.
Citation
Gökalp Urul (2018). Energy Efficient Dynamic Virtual Machine Allocation with CPU Usage Prediction in Cloud Datacenters. Bilkent University. M.Sc. thesis, Computer Engineering, January 2018. https://repository.bilkent.edu.tr/server/api/core/bitstreams/e13b8cbf-2ad9-4437-81c2-9e32ca1f0f4b/content
All content and rights belong to the respective authors and publishers. SoSo CAD provides only the citation, its own summary and a link to the source, and is not responsible for the sources' content.