Research paperFree to read2020

Server and Wireless Network Resource Allocation Strategies in Heterogeneous Cloud Data Centers

Bilkent University · Cem Mergenci

A Bilkent University PhD thesis (August 2020) that proposes two new metrics for placing virtual machines as vector bin packing and studies traffic offloading in a hybrid wireless data centre with two 60 GHz 802.11ad radios and three channels per rack switch.

On this page

Overview

The thesis examines the allocation of two main resource types in data-centre operation: servers and network links. Server resources (CPU, memory, storage, IO, GPU and others) are modelled as a multidimensional vector space, and placing virtual machines (VMs) on physical machines (PMs) is treated as vector bin packing with heterogeneous bins (VBPHB). The author defines design criteria for metrics that measure the fitness of an allocation, proposes two novel metrics that meet them and presents allocation heuristics that use them. In the VBPHB benchmark the proposed metrics find feasible solutions to more allocation problems than other metrics from the literature.

The network part addresses the hybrid wireless data centre. In the system model each top-of-rack (ToR) switch has two radios operating in the 60 GHz band using three-channel 802.11ad. The thesis shows that the three worldwide-available non-overlapping 802.11ad channels suffice for an interference-free channel assignment to any configuration of links that can be formed. Given traffic demand between ToR switches, the links that maximise the traffic carried over the wireless network are determined. The proposed methods are two families, shortest-path (SP) and longer-path-capable (LP), with four versions each; traffic the wireless network cannot carry is routed over the wired network.

Performance is measured with randomly generated traffic based on probability distributions fitted to a real data-centre traffic pattern (Cosmos); the method can generate traffic for different network sizes (for example 16, 25, 36 and 49 nodes). Results show that the proposed methods offload a significant amount of traffic from wired to wireless with low latency, high throughput and high bandwidth utilisation. The Cosmos dataset is not public; the pattern was reverse-engineered from published work.

This is a research thesis and its results are simulation findings with generated traffic; they should not be presented as a deployment acceptance criterion. As future work the author proposes proximity-constrained VM placement, reducing network distance between VMs with wireless resources, and dynamic wireless links by workload to avoid VM migration cost; the author also notes that wireless communication cannot reduce the distance between physically distant VMs, so VMs should be placed in racks physically close to each other.

Key points

  1. A Bilkent University Computer Engineering PhD thesis dated August 2020 (advisor İbrahim Körpeoğlu).
  2. Server resources are modelled as a multidimensional vector space; placing VMs on PMs is vector bin packing with heterogeneous bins (VBPHB).
  3. The author defines design criteria and proposes two novel metrics meeting them, plus allocation methods that use them.
  4. In the VBPHB benchmark the proposed metrics find feasible solutions to more problems than other metrics.
  5. In the hybrid network model each ToR switch has two radios in the 60 GHz band using three-channel 802.11ad.
  6. Three non-overlapping 802.11ad channels are shown to suffice for interference-free channel assignment for any link configuration.
  7. Traffic offloading uses SP (shortest-path) and LP (longer-path-capable) families, each with one original and three modified algorithms.
  8. Evaluation uses random traffic derived from a real data-centre traffic pattern (Cosmos) and networks of 16, 25, 36 and 49 nodes.
  9. Results show significant traffic offloaded from wired to wireless, with low latency and high throughput and bandwidth utilisation.

Using it in design

  • In VM placement policy, treat CPU, memory, storage, IO and GPU as a multidimensional vector and define a metric that measures placement fitness.
  • In a heterogeneous server fleet, compare placement algorithms with VBPHB-like benchmarks to validate the scheduler you use.
  • If considering 60 GHz wireless links between rack switches, remember they need line of sight and that this thesis's evaluation is simulation with generated traffic.
  • Treat wireless links as added capacity for hot spots, complementing rather than replacing the wired network; add to acceptance tests that traffic the wireless links cannot carry falls back to wired.
  • Add a proximity constraint to placement rules so VMs that communicate heavily sit in physically close racks.

Who should read it

Academics, cloud-platform engineers and network architects researching data-centre resource management, VM placement and hybrid wireless networks.

Document contents

  1. Introduction: thesis outline
  2. Related work: server resource allocation, hybrid wireless data-centre networking
  3. Metrics for allocation of server resources: multidimensional resource allocation problem, proposed utilisation metrics, other metrics
  4. Algorithms for allocation of server resources: algorithms based on the metrics, simulation experiments and evaluation
  5. Allocation of wireless network resources in data centres: system model, proposed method
  6. Data-centre traffic model and performance evaluation: Cosmos traffic analysis, simulations and results
  7. Conclusion and future work

Publication details

Authors
Cem Mergenci
Publisher
Bilkent University
Year
2020
Document number
Ph.D. thesis, Computer Engineering, August 2020
Document language
English
Source type
Scientific
Access
Free to read
Licence
Copyright retained; citation only: the publisher’s terms apply to the original document
Original licence note

Official publisher or university publicly accessible text; no open redistribution licence established.

Citation

Cem Mergenci (2020). Server and Wireless Network Resource Allocation Strategies in Heterogeneous Cloud Data Centers. Bilkent University. Ph.D. thesis, Computer Engineering, August 2020. https://repository.bilkent.edu.tr/server/api/core/bitstreams/a20e39b3-8e72-49cf-bc5a-d44c52c5c70a/content

All content and rights belong to the respective authors and publishers. SoSo CAD provides only the citation, its own summary and a link to the source, and is not responsible for the sources' content.

Cost studies in SoSo CAD

Calculate equipment cost, energy cost and total cost of ownership (TCO) from the design’s quantities and your own price assumptions.

CAPEX and TCO estimates in the SoSo CAD cost workspace

Keep your reading list current

Once a month: new library sources, changes to Turkish regulations and upcoming data centre events.