Network-Aware Virtual Machine Placement in Cloud Data Centers with Multiple Traffic-Intensive Components
Bilkent University · Amir Rahimzadeh Ilkhechi
A 2014 Bilkent M.Sc. thesis presenting greedy and heuristic algorithms for the NP-hard placement problem in cloud data centres where VMs exchange intensive traffic with fixed sink nodes.
On this page
Overview
This July 2014 M.Sc. thesis by Amir Rahimzadeh Ilkhechi studies network- and traffic-aware virtual machine (VM) placement from the cloud infrastructure provider's perspective. In the scenario of interest, certain infrastructure components (sink nodes) are sources or targets of many intensive traffic flows initiated or targeted by VMs, while inter-VM traffic is negligible. VM performance therefore depends directly on the infrastructure's ability to meet these demands.
The author defines a 'satisfaction' metric reflecting how suitable a physical machine (PM) is for a VM placed on it, and aims to maximise total satisfaction. When congestion is taken into account the problem resembles the Quadratic Assignment Problem: it is NP-hard and no polynomial-time algorithm yields an optimal solution. Offline greedy and heuristic algorithms are therefore proposed, assuming the communication pattern and flow demand profiles of the VMs are known in advance.
Evaluation uses simulation experiments over different problem sizes, network topologies and demand distributions. The proposed algorithms are significantly more effective than random assignment (the difference depends on topology and demand distribution) and perform consistently across sizes. Two variants of each approach are also compared. The experiments further show that overall data centre network congestion and total satisfaction are correlated.
The limits are stated plainly: demands must be known in advance, which is unrealistic in many situations, and an online variant is left for future work. Capacity limits of the sinks themselves are not modelled. The work is an algorithm and simulation thesis; it does not address physical data centre design, cooling or power.
Key points
- Scenario: VMs exchange intensive traffic with fixed sink nodes; inter-VM traffic is negligible.
- The 'satisfaction' metric represents the performance suitability of a VM on a given PM and correlates with network congestion.
- With congestion considered, the problem resembles the Quadratic Assignment Problem and is NP-hard.
- The solutions are offline greedy and heuristic algorithms that assume communication patterns and flow demand profiles are known in advance.
- In simulation the algorithms are significantly more effective than random assignment; the gain depends on topology and demand distribution.
- Each approach has two variants; the algorithms perform consistently across problem sizes.
- A correlation between total network congestion and total satisfaction was observed.
- Future work: sink capacity limits, an online variant and graphical congestion games.
Using it in design
- Design the location of heavy-traffic nodes such as storage or external gateways together with the VM placement policy, and reflect placement near sinks in the network capacity plan.
- When choosing a placement scheduler, assess whether the traffic demand profile is known and whether an offline solution is adequate.
- Add as a design criterion that reducing congestion directly affects VM performance, so oversubscription ratios on links near sinks should be checked separately.
- Results rest on simulation; validate them on the real topology.
Who should read it
Engineers and academics developing cloud resource management and placement algorithms, and teams planning data centre network capacity.
Document contents
- Introduction
- Background and Related Work (cloud computing, service assignment problems)
- Problem Definition (scenario, assumptions, mathematical description)
- Proposed Algorithms (greedy approach, heuristic-based approach, worst-case complexity)
- Simulation Experiments and Evaluation
- Conclusion and Future Work
Publication details
- Authors
- Amir Rahimzadeh Ilkhechi
- Publisher
- Bilkent University
- Year
- 2014
- Document number
- M.Sc. thesis, Computer Engineering, July 2014
- Document language
- English
- Source type
- Scientific
- Access
- Free to read
- Licence
- Copyright retained; citation only: the publisher’s terms apply to the original document
Original licence note
Official publisher or university publicly accessible text; no open redistribution licence established.
Citation
Amir Rahimzadeh Ilkhechi (2014). Network-Aware Virtual Machine Placement in Cloud Data Centers with Multiple Traffic-Intensive Components. Bilkent University. M.Sc. thesis, Computer Engineering, July 2014. https://repository.bilkent.edu.tr/bitstreams/c2fe1988-b5d3-47db-b73d-da2261f0bba5/download
All content and rights belong to the respective authors and publishers. SoSo CAD provides only the citation, its own summary and a link to the source, and is not responsible for the sources' content.