Building AI/ML Data Center Fabric using VXLAN EVPN for GPUaaS
Cisco
Cisco's March 2026 design guide describes a rail-optimized, non-blocking VXLAN EVPN fabric of 24 leaves and 16 spines for 96 GPU servers, and a multitenant GPU-as-a-Service use case.
On this page
Overview
The guide is a blueprint for building AI/ML networks with Cisco Nexus 9000 switches and a VXLAN EVPN fabric, based on a real deployment: Cisco UCS-C885A-M8-H26 dense GPU servers connected to a fabric of Nexus 9300 ToR switches managed by Nexus Dashboard 4.1. The use case runs 88 servers and scales to 96 servers (8 GPUs each, 768 GPUs total). Of the eBGP routed and VXLAN EVPN fabric templates, the VXLAN EVPN template is used because it supports multi-tenancy.
The topology is a two-tier spine-leaf. The network is organised into three scalable units (SUs) of 8 leaves; each SU connects 32 servers (the last unit 24, expandable to 32). The target is 8 GPUs per server and 400 Gbps per GPU. In the rail-optimized design the same GPU position (for example GPU 0) on different servers connects to the same leaf: Leaf 1 to GPU0 of 32 servers, Leaf 2 to GPU1, through Leaf 8. This keeps parallel communication such as NCCL on optimised paths and reduces hops.
There are 24 leaves and 16 spines in total; each leaf has 32 uplinks and connects to every spine with 2 x 400G, giving a non-blocking fabric at line rate. The leaf switch, Nexus 9364D-GX2A, is 2RU, SoC-based, with 4 slice pairs of 16 x 400G ports and 30 MB buffer each (120 MB total). Buffer matters for absorbing microbursts and supporting lossless transport such as RoCEv2 with PFC. In the cable matrix ports 1 to 4 of each slice serve GPU servers and ports 5 to 8 serve spine uplinks, with uplinks spread evenly across slices.
The technology section describes RoCEv2, PFC, ECN and CNP and states that PFC and ECN together turn Ethernet from lossy to lossless. Cisco Intelligent Packet Flow has four pillars: advanced load balancing, hardware-accelerated telemetry, fault-aware recovery and congestion management. In the multitenant example Customer A receives 2 servers (16 GPUs) and Customer B 4 servers (32 GPUs), with the cable matrix identifying the leaf ports; segmentation and provisioning are done through Nexus Dashboard. The guide is a vendor document: its choices are platform-specific and not universal fabric requirements.
Key points
- The fabric has 24 leaves and 16 spines for 96 GPU servers (768 GPUs), with 8 GPUs per server at 400 Gbps per GPU.
- Scalable unit (SU): 8 leaves and 32 servers; the fabric has three SUs and can grow to 4.
- Rail-optimized mapping: the same GPU index on different servers connects to the same leaf (Leaf 1 = GPU0, Leaf 8 = GPU7).
- Each leaf has 32 uplinks and connects to each spine with 2 x 400G; the fabric is non-blocking.
- Nexus 9364D-GX2A: 2RU, 4 slice pairs, 16 x 400G and 30 MB buffer per pair, 120 MB total buffer.
- Per slice, ports 1 to 4 serve GPU servers and 5 to 8 serve spine uplinks; uplinks are spread across slices.
- PFC and ECN together make Ethernet lossless; RoCEv2 and CNP handle congestion notification.
- Multitenant example: Customer A 2 servers (16 GPUs), Customer B 4 servers (32 GPUs); VXLAN EVPN segmentation, Nexus Dashboard provisioning.
Using it in design
- Define a scalable unit for the GPU cluster (for example 8 leaves and 32 servers) and replicate rail-optimized cabling per unit.
- Compute the leaf uplink ratio to be non-blocking: this guide uses 32 uplinks per leaf and 2 x 400G to each spine.
- Plan 8 x 400G per server with leaf port and slice mapping; spread uplinks across all slices for buffer balance.
- For multitenant GPUaaS, document the VXLAN EVPN template, per-tenant VRF and segment design, and server-to-leaf port assignment.
- Tie RoCEv2 PFC and ECN thresholds and switch buffer (for example 120 MB total) to acceptance criteria.
- Do not treat the guide's choices as universal requirements; recompute for your own GPU server and switch model.
Who should read it
Network architects designing AI and GPU cluster networks, GPU-as-a-Service providers and Cisco Nexus fabric engineers.
Document contents
- Introduction
- Design Concept and Customer Use Case: high performance and scalability, rail-optimized mapping, network segmentation and security, future-proof foundation, key outcomes
- Technology Overview: building a non-blocking rail-optimized network for AI/ML, components used
- Cisco Nexus 9364D-GX2A Overview: slice pair architecture and buffering, benefits for AI/ML
- Cable Matrix and Buffer Optimization: leaf port allocation per slice, spine uplink strategy, GPU downlink strategy
- Step-by-step Configuration using Cisco Nexus Dashboard
- Use Case: Multi-Tenant GPU-as-a-Service: resource assignments, segmentation and provisioning, advanced telemetry and L3 segmentation
- Summary
Publication details
- Authors
- Cisco
- Publisher
- Cisco
- Year
- 2026
- Document language
- English
- Source type
- Manufacturer
- Access
- Free to read
- Licence
- Copyright retained; citation only: the publisher’s terms apply to the original document
Original licence note
Publisher source opened. No document-specific commercial redistribution permission established; link and original metadata only.
Citation
Cisco (2026). Building AI/ML Data Center Fabric using VXLAN EVPN for GPUaaS. Cisco. https://cisco.com/c/en/us/td/docs/dcn/whitepapers/building-aiml-dc-fabric-using-vxlan-evpn-for-gpuaas.html
All content and rights belong to the respective authors and publishers. SoSo CAD provides only the citation, its own summary and a link to the source, and is not responsible for the sources' content.