Data Centres Metered Electricity Consumption 2024

Central Statistics Office (Ireland) · Central Statistics Office (CSO) Ireland

Ireland's Central Statistics Office reported on 10 June 2025 that metered electricity use by data centres rose 10% in 2024 to 6,969 GWh, reaching 22% of all metered consumption in the country.

On this page

Overview

The release is the latest edition of the official statistical series tracking metered electricity use by Irish data centres on an annual and quarterly basis from 2015 to 2024. Data-centre consumption was 6,335 GWh in 2023 and 6,969 GWh in 2024, while consumption by all other users grew by only 3% over the same period. It is a CSO statistical release dated 10 June 2025, 11am, carrying ISSN 2811-5422.

The data-centre share of total metered consumption rose from 5% in 2015 to 22% in 2024. In the intervening years the share climbed through 6, 7, 8, 9, 11, 14, 18 and 21 percent, so the increase reflects a steady decade-long build-up rather than a single jump. Total metered consumption grew 30% between 2015 and 2024, to 31,903 GWh.

The quarterly series is even starker: data-centre use went from 290 GWh in the first quarter of 2015 to 1,829 GWh in the fourth quarter of 2024, an increase of 531%. In 2024 urban households accounted for 18% of the total and rural households 10%, while large energy users, a category that usually includes the larger data centres, took the biggest share at 31% (9,897 GWh, up 9% on the previous year).

There is one important methodological limit: data centres are not a separate class in the source data. The CSO identifies them through name searches for known operators, industry reports and internet research, and by examining the business sector of high-consumption customers. The series is therefore a national benchmark built on classification work, not on site-level measurement.

Key points

  1. Data-centre consumption rose 10%, from 6,335 GWh in 2023 to 6,969 GWh in 2024; all other users rose 3%.
  2. The data-centre share of metered electricity was 5% in 2015, 11% in 2020, 18% in 2022 and 22% in 2024.
  3. Total metered consumption reached 31,903 GWh in 2024, up 30% between 2015 and 2024.
  4. Quarterly data-centre consumption grew from 290 GWh (Q1 2015) to 1,829 GWh (Q4 2024), an increase of 531%.
  5. Annual data-centre consumption was 1,238 GWh in 2015, 2,180 GWh in 2018, 4,010 GWh in 2021 and 5,270 GWh in 2022.
  6. Urban households used 18% of the total and rural households 10%.
  7. Large energy users formed the biggest class with a 31% share and 9,897 GWh, up 9% on the prior year.
  8. Data centres are not separately classified in the source data; the CSO finds them through operator-name searches, industry reports and review of high-consumption customers.

Using it in design

  • Use the Irish series, with annual growth in the 10-30% range, as a national-scale reference in grid-connection requests and load growth scenarios.
  • In grid-capacity and permitting risk analysis, account for how connection constraints tighten in a market where the data-centre share went from 5% to 22%.
  • When modelling national data-centre load, note the CSO classification method and treat the data as a classified estimate, not as site measurement.
  • Use the quarterly series to test assumptions about intra-year load profiles and the rising trend in capacity planning.

Who should read it

Energy planners, design teams managing grid-connection and permitting processes, policy analysts and engineers who want to benchmark national-scale data-centre load.

Document contents

  1. Key Findings
  2. Statistician's Comment
  3. CSO Identification of a Data Centre
  4. Table 1: Metered Electricity Consumption 2015-2024
  5. Table 2: Data Centres Metered Electricity Consumption by Quarter 2015-2024

Publication details

Authors
Central Statistics Office (CSO) Ireland
Publisher
Central Statistics Office (Ireland)
Year
2025
Document number
ISSN 2811-5422
Document language
English
Source type
Expert / community
Access
Free to read
Licence
Copyright retained; citation only: the publisher’s terms apply to the original document
Original licence note

CSO page links to its Copyright and Re-use Policy; no licence stated on the page itself.

Citation

Central Statistics Office (CSO) Ireland (2025). Data Centres Metered Electricity Consumption 2024. Central Statistics Office (Ireland). ISSN 2811-5422. https://www.cso.ie/en/releasesandpublications/ep/p-dcmec/datacentresmeteredelectricityconsumption2024/keyfindings/

All content and rights belong to the respective authors and publishers. SoSo CAD provides only the citation, its own summary and a link to the source, and is not responsible for the sources' content.

Cost studies in SoSo CAD

Calculate equipment cost, energy cost and total cost of ownership (TCO) from the design’s quantities and your own price assumptions.

CAPEX and TCO estimates in the SoSo CAD cost workspace

Keep your reading list current

Once a month: new library sources, changes to Turkish regulations and upcoming data centre events.