Technical guideFree to read2026

Data center solutions powering the digital economy

Danfoss

A Danfoss portfolio brochure (India edition) mapping its products onto data-centre cooling and power subsystems; a component checklist for a cooling plant rather than a design method.

On this page

Overview

The brochure covers air-cooled chillers, precision air units, liquid-cooling connectors and CDU components, pump stations, solid-state transformers, heat-recovery modules and fan walls. Each section lists the relevant components (Turbocor compressors, VFDs, micro-channel and plate heat exchangers, balancing valves, couplings, sensors) with headline performance figures.

On the cooling side: Turbocor oil-free compressors are quoted with up to 38 °C maximum chilled-water output for air-cooled chillers; all-aluminium micro-channel heat exchangers are claimed to give up to 30% better performance with lower refrigerant charge and glycol compatibility for dry/free cooling; gasketed plate heat exchangers reach an approach temperature as low as 1 °C.

On the electrical side, iC7 ULH air-cooled pump drives are quoted at 3-5% THDi or less, with ultra-low supraharmonics and no common-mode voltage. An Advanced Active Filter with SiC switches is quoted at 98.2% efficiency. The solid-state transformer converts MV AC directly to LV DC with a single 11 MW converter.

For liquid cooling, OCP-inspired UQD/UQDB couplings are used in-rack and FD83 couplings out-of-rack on CDU loops. The figures are the manufacturer's own promotional values and their test conditions are not detailed in the brochure.

Key points

  1. Turbocor oil-free compressors are quoted with up to 38 °C maximum chilled-water output in air-cooled chillers.
  2. All-aluminium micro-channel heat exchangers: up to 30% better performance, lower refrigerant charge, glycol-compatible.
  3. iC7 ULH pump drives quoted at 3-5% THDi or less, ultra-low supraharmonics, no common-mode voltage.
  4. Advanced Active Filter with SiC switches quoted at 98.2% efficiency.
  5. Gasketed plate heat exchangers reach approach temperatures as low as 1 °C.
  6. OCP-inspired UQD/UQDB couplings in-rack and FD83 couplings out-of-rack for CDU loops.
  7. The solid-state transformer converts MV AC to LV DC with a single 11 MW converter.

Using it in design

  • Keep a component schedule for each cooling subsystem-chiller, CDU, pump skid and heat recovery-with maximum chilled-water temperature, heat-exchanger approach temperature and VFD THDi.
  • When liquid cooling is selected, require the in-rack and out-of-rack quick-disconnect types to be specified.
  • Model low-harmonic drives as reduced harmonic sources in the power-quality calculation.

Who should read it

Mechanical designers and procurement teams scanning the component scope of a data-centre cooling plant.

Related standards

  • OCP UQD specification
  • AHRI

Publication details

Authors
Danfoss
Publisher
Danfoss
Year
2026
Document number
AM570745408300en-IN0101
Document language
English
Source type
Manufacturer
Access
Free to read
Licence
Copyright retained; citation only: the publisher’s terms apply to the original document

Citation

Danfoss (2026). Data center solutions powering the digital economy. Danfoss. AM570745408300en-IN0101. https://assets.danfoss.com/documents/latest/600967/AM570745408300en-IN0101.pdf

All content and rights belong to the respective authors and publishers. SoSo CAD provides only the citation, its own summary and a link to the source, and is not responsible for the sources' content.

Cooling capacity in SoSo CAD

Check zone heat loads, installed capacity and the capacity left with the largest unit out, as part of the design.

Zone heat loads and capacity balance in the SoSo CAD cooling workspace

Keep your reading list current

Once a month: new library sources, changes to Turkish regulations and upcoming data centre events.