Deploying 800VDC Architectures for Large-Amperage Data Centers
Eaton · Steven Johnston, Alexandra Rangel-Santos et al.
Eaton's 2026 white paper (WP017005EN) on modular 800 V DC infrastructure, covering source fault behaviour, grounding, protection coordination, inrush and grid ride-through.
On this page
Overview
The white paper examines design issues for modular 800 V DC infrastructure in large-amperage data centres. The topics covered are source fault behaviour, grounding, protection coordination, inrush at energisation and grid ride-through. In DC distribution the fault current comes from power converters, so the protection approach built on high, sustained short-circuit current in AC systems does not apply directly.
The coordination discussion covers not only upstream breakers but also power converters and rack-level protective devices. For resistance-grounded systems, it states that pole-to-ground faults may require dedicated detection rather than conventional overcurrent detection.
Key points
- Subject: modular 800 V DC infrastructure and large-amperage data centres.
- Source fault behaviour, grounding, protection coordination, inrush and grid ride-through are covered.
- In resistance-grounded systems, pole-to-ground faults may require dedicated detection rather than conventional overcurrent detection.
- Protection coordination includes upstream breakers, power converters and rack-level protective devices together.
Using it in design
- For 800 V DC distribution, choose the grounding method (for example resistance grounding) and define separate detection for pole-to-ground faults.
- In the protection coordination study, include converter current limits and rack-level protective devices as well as breakers.
- Set inrush at energisation and ride-through behaviour during grid faults as design criteria.
- Take the source fault-current level from converter data and verify protective-device selection against it.
Who should read it
Electrical engineers designing 800 V DC data-centre distribution and those performing protection coordination.
Publication details
- Authors
- Steven Johnston; Alexandra Rangel-Santos; Anthony Parsons; Bruce Campbell; Swanand Jukevar; Xin Zhou; Brian Tureski; Jacob Chacko
- Publisher
- Eaton
- Year
- 2026
- Document number
- WP017005EN
- Document language
- English
- Source type
- Manufacturer
- Access
- Free to read
- Licence
- Copyright retained; citation only: the publisher’s terms apply to the original document
Original licence note
Official public manufacturer source inspected. No redistribution permission established. Metadata and original brief summaries only; local files are research evidence, not a redistribution package.
Citation
Steven Johnston; Alexandra Rangel-Santos; Anthony Parsons; Bruce Campbell; Swanand Jukevar; Xin Zhou; Brian Tureski; Jacob Chacko (2026). Deploying 800VDC Architectures for Large-Amperage Data Centers. Eaton. WP017005EN. https://www.eaton.com/content/dam/eaton/markets/data-center/the-impact-of-ai/whitepapers/eaton-deploying-800vdc-architecture-whitepaper-en-us.pdf
All content and rights belong to the respective authors and publishers. SoSo CAD provides only the citation, its own summary and a link to the source, and is not responsible for the sources' content.