Accounting carbon emissions from electricity generation: a review and comparison of emission factor-based methods
Applied Energy (Elsevier BV) · Marina Bertolini, Pierdomenico Duttilo et al.
The paper reviews emission-factor methods for estimating direct CO2 emissions from electricity generation, organised by the IPCC 2006 Tier 1/2/3 framework, and compares six methods on hourly ENTSO-E generation data for the seven Italian market zones over 2016-2023.
CC BY 4.0: share with attribution
On this page
Overview
Accurate estimation of greenhouse gas emissions is essential to meet carbon-neutrality targets, particularly through calculating direct CO2 emissions from electricity generation. The basic emission formula is E = activity data × emission factor; Tier 1 uses IPCC default factors, Tier 2 country-specific factors and Tier 3 plant/technology-specific data. Fuel emission factors used (IPCC default): fossil coal 94.60 tCO2/TJ, natural gas 56.10, fossil oil 77.7, derived gas 107.07; the Italian (ISPRA) derived-gas factor is 163.36 tCO2/TJ.
The methods produce very different totals: three simple formulations underestimate emissions by about 73% against the best estimates. North zone 2022: Method 5 (Tier 2, ISPRA factors, with CO2/C molecular-weight ratio) gave the highest estimate, about 57.5 Mt CO2; Method 4 was about 2% lower, Method 6 (Tier 3-type Carbon Monitor adjustment) almost 11% lower, and Methods 1-3 about 73% lower. Average yearly emission factor (AEF) for the North zone by Method 5 rose from 0.1627 tCO2/MWh in 2016 to 0.4709 in 2022, then fell to 0.3936 in 2023.
For 2018 in Northern Italy, the plant-level Tier 3 approach of Beltrami et al. gave 36,625,956 tCO2 and an AEF of 0.2840 tCO2/MWh, differing from Method 5 by 8% in emissions and 9% in AEF. 2023 AEF for the island zones depends strongly on the factor source: Sicily 0.5939 (Method 4) vs 0.4937 tCO2/MWh (Method 5), and Sardinia 0.9984 vs 0.7265, because of the derived-gas factor (IPCC 0.39 vs ISPRA 0.59 tCO2/MWh). Adding the carbon oxidation fraction (Method 3) made little difference, and a Tier 3 label did not guarantee higher accuracy: the Tier 3-type Method 6 underestimated relative to Tier 1/2 Methods 4-5.
The finding is that accuracy does not rank cleanly by tier, and country- or zone-specific factors matter most where fuels such as derived gases are significant; applied in the correct context, Tier 1 methods can also perform well. The paper focuses on generation-side (production-based) average emission factors and does not address marginal factors.
Key points
- The basic emission formula is E = activity data × emission factor; Tier 1 uses IPCC defaults, Tier 2 country-specific factors, Tier 3 plant/technology-specific data.
- Fuel emission factors (IPCC default): fossil coal 94.60 tCO2/TJ, natural gas 56.10, fossil oil 77.7, derived gas 107.07; the Italian (ISPRA) derived-gas factor is 163.36 tCO2/TJ.
- North zone 2022: Method 5 gave the highest estimate (about 57.5 Mt CO2); Method 4 about 2% lower, Method 6 almost 11% lower, Methods 1-3 about 73% lower.
- AEF for the North zone by Method 5 rose from 0.1627 tCO2/MWh in 2016 to 0.4709 in 2022, then fell to 0.3936 in 2023.
- For 2018 in Northern Italy, the plant-level Tier 3 approach gave 36,625,956 tCO2 and an AEF of 0.2840 tCO2/MWh, differing from Method 5 by 8% in emissions and 9% in AEF.
- 2023 AEF for the island zones depends strongly on the factor source: Sicily 0.5939 (Method 4) vs 0.4937 (Method 5), Sardinia 0.9984 vs 0.7265 tCO2/MWh; the cause is the derived-gas factor (IPCC 0.39 vs ISPRA 0.59 tCO2/MWh).
- Adding the carbon oxidation fraction (Method 3) made little difference; a Tier 3 label did not guarantee higher accuracy.
Using it in design
- In data-centre carbon accounting, state the method (Tier 1, 2, 3) and factor source (IPCC or national) when choosing a grid emission factor; simple methods can underestimate generation emissions by about 73%.
- Use country- or zone-specific factors where derived gas and similar fuels have a significant share; in the island zones factor choice changed AEF by 20-37%.
- Note in the report that a production-based average factor does not represent marginal impact and that marginal approaches are needed for load-shifting or siting decisions.
Who should read it
Sustainability analysts choosing electricity emission-factor methods and doing data-centre Scope 2 accounting.
Document contents
- 1 Introduction
- 2 Review of emission-factor-based methods under the IPCC Tier 1/2/3 framework
- 3 Comparison of methods: six methods, Italian market zones, hourly ENTSO-E data 2016-2023
- 4 Results
- 5 Discussion
- 6 Conclusions
Related standards
- GHG Protocol Corporate Standard
- IPCC 2006 Guidelines for National Greenhouse Gas Inventories
Read the document
electricity-emission-factor-methods-review-2025.pdf
CC BY 4.0: share with attribution
The document is provided unaltered because its licence permits redistribution.
Publication details
- Authors
- Marina Bertolini; Pierdomenico Duttilo; Francesco Lisi
- Publisher
- Applied Energy (Elsevier BV)
- Year
- 2025
- Document number
- arXiv:2411.13663
- Volume
- 392
- Pages
- 125992
- Document language
- English
- Source type
- Scientific
- Access
- Open licence (downloadable)
- Licence
- CC BY 4.0: share with attribution
- Licence evidence
- arxiv.org
Original licence note
arXiv OAI-PMH record for 2411.13663 gives license http://creativecommons.org/licenses/by/4.0/. Downloaded file is the arXiv author version of the published (CC-BY) journal article; url points to the journal DOI.
Citation
Marina Bertolini; Pierdomenico Duttilo; Francesco Lisi (2025). Accounting carbon emissions from electricity generation: a review and comparison of emission factor-based methods. Applied Energy (Elsevier BV). arXiv:2411.13663. 392, 125992. https://doi.org/10.1016/j.apenergy.2025.125992
All content and rights belong to the respective authors and publishers. SoSo CAD provides only the citation, its own summary and a link to the source, and is not responsible for the sources' content.