Topic

Sustainability

Browse publications on environmental impacts, carbon, resource use and life cycles. Compare assessment methods while reviewing their scope, data periods and reporting boundaries alongside the original sources.

Key numbers

Values hold under the conditions stated in each source. Read the cited page before using one in your project.

QuantityValueConditionSource
World average grid carbon intensity475 gCO2e/kWhSome grids fall below 60 gCO2e/kWhJournal of Science Policy & Governance (Journal of Science Policy and Governance, Inc.), 2026 · p. 5
Embodied carbon added to the operational footprint15-25%Extended boundary; 2.5–3.5 tCO2e per AI-optimised serverFrontiers in Environmental Science (Frontiers Media SA), 2026 · p. 14
Renewable or hourly carbon-free matching (end of 2025)75%100% by 31 Dec 2030Climate Neutral Data Centre Pact (CNDCP), 2025 · p. 1, Clean Energy
Norway: heat reuse assessment threshold2 MWRecommended since 2021Open Compute Project Foundation, 2024 · p. 15
Maximum refrigerant GWP in the cooling system675EU taxonomy, criterion 3European Commission, 2021 · p. 133
Proposed operational PUE limitoperational PUE < 1.5 by 2030For sites commissioned before 2027; design PUE below 1.3 for new sitesEuropean Commission, DG ENER (AIT, Borderstep Institute, EY), 2025 · p. 52

Design checklist

  1. Check the method field before summing or comparing values calculated by different methods. (Open Compute Project Foundation, 2025)
  2. Plan separate metering for renewable energy, reuse energy export and water withdrawal and consumption, since these feed REF, ERF and WUE. (Open Compute Project Foundation, 2024)
  3. Track renewable sources (guarantees of origin, PPA, on-site generation) separately. (European Commission (Official Journal of the European Union), 2024)
  4. Assess PUE, CUE, WUE/source WUE and IT productivity together so low PUE is read alongside carbon, water and useful work. (Journal of Science Policy & Governance (Journal of Science Policy and Governance, Inc.), 2026)
  5. When TCS is 40 °C or higher, consider switching off adiabatic assist and show the water-versus-energy difference. (Schneider Electric, 2026)

Start with these sources

Is Power Usage Effectiveness (PUE) Still Fit for Purpose? An Integrative Review of Data Center Metrics for Assessing the Environmental Impact of Modern AI Infrastructure

Journal of Science Policy & Governance (Journal of Science Policy and Governance, Inc.), 2026, Research paper

A policy-oriented integrative review asking whether PUE still works for high-density AI facilities, identifying four blind spots and proposing a four-axis dashboard instead of a single metric.

Research paper

2026

Read at publisher (opens in a new tab)

Related standards and regulations

Calculators and product

Cost studies in SoSo CAD

Calculate equipment cost, energy cost and total cost of ownership (TCO) from the design’s quantities and your own price assumptions.

CAPEX and TCO estimates in the SoSo CAD cost workspace

All documents in this topic

1–24 / 343

Is Power Usage Effectiveness (PUE) Still Fit for Purpose? An Integrative Review of Data Center Metrics for Assessing the Environmental Impact of Modern AI Infrastructure

Journal of Science Policy & Governance (Journal of Science Policy and Governance, Inc.), 2026, Research paper

A policy-oriented integrative review asking whether PUE still works for high-density AI facilities, identifying four blind spots and proposing a four-axis dashboard instead of a single metric.

Research paper

2026

Read at publisher (opens in a new tab)