Commission Delegated Regulation (EU) 2021/2139 of 4 June 2021 supplementing Regulation (EU) 2020/852 by establishing the technical screening criteria for determining the conditions under which an economic activity qualifies as contributing substantially to climate change mitigation or climate change adaptation and for determining whether that economic activity causes no significant harm to any of the other environmental objectives (EU Taxonomy Climate Delegated Act)

Original title Commission Delegated Regulation (EU) 2021/2139 of 4 June 2021 supplementing Regulation (EU) 2020/852 - EU Taxonomy Climate Delegated Act (incl. activity 8.1 Data processing, hosting and related activities)

European Commission

The act sets the technical screening criteria for the climate objectives of the EU Taxonomy. For data centres, activity 8.1 "Data processing, hosting and related activities" is treated as a transitional activity tied to EU Code of Conduct compliance, a refrigerant GWP limit and do-no-significant-harm conditions.

EU reuse (2011/833/EU): reuse permitted with acknowledgement of the source

On this page

Overview

The Delegated Regulation sets the technical screening criteria required by Articles 10(3) and 11(3) of the Taxonomy Regulation (EU) 2020/852. Article 1 puts the climate change mitigation criteria in Annex I and Article 2 the adaptation criteria in Annex II; the Regulation applies from 1 January 2022. The criteria build on existing Union law, best practice and standards, and state the minimum requirements for an activity both to contribute substantially to the climate objective and to do no significant harm (DNSH) to the other environmental objectives. Annex I covers sectors such as forestry, manufacturing, energy, water and waste, transport, construction and real estate, information and communication and professional activities.

Data centres sit in Annex I under activity 8.1 (NACE J63.11). The activity covers storage, processing, transmission and related handling of data through data centres, including edge computing, and data centres include ICT equipment, cooling, power and power distribution equipment, the building and monitoring systems. It is a transitional activity under Article 10(2) of the Taxonomy Regulation, and holds that status only where it meets the technical screening criteria in the section.

Substantial contribution to mitigation rests on three criteria. First, implement all relevant "expected practices" of the most recent EU Code of Conduct on Data Centre Energy Efficiency or CLC TR 50600-99-1, verified by an independent third party and audited at least every three years. Second, where an expected practice is not relevant because of physical, logistical, planning or other constraints, explain why, and alternative practices with similar energy savings may be identified as direct replacements. Third, the global warming potential (GWP) of refrigerants in the cooling system must not exceed 675.

DNSH criteria cover the other objectives. For adaptation Appendix A (climate risk and vulnerability assessment against listed hazards) applies and for water Appendix B (good water status, water use and protection management plan). For the circular economy, equipment must meet Directive 2009/125/EC requirements for servers and data storage, not contain RoHS Annex II restricted substances (apart from allowed concentration values in homogeneous materials), a waste management plan must ensure maximal recycling, and end-of-life equipment gets selective treatment under WEEE Annex VII. Pollution prevention and biodiversity are marked N/A for this activity.

Annex II describes substantial contribution to adaptation for the same activity: the activity must implement solutions that substantially reduce the physical climate risks material to it. Risks are screened against Appendix A (temperature, wind, water and solid mass related chronic and acute hazards, for example heat stress, heat wave, water stress, flood, sea level rise); activities with an expected lifespan under 10 years use climate projections at the smallest appropriate scale, others use the highest available resolution, with at least 10 to 30 year projections for major investments. Under adaptation, the mitigation DNSH also requires all expected practices rated with the maximum value of 5 in the Code of Conduct. This is the original 2021 Official Journal text; later amendments are not consolidated here.

Key points

  1. Article 1 puts mitigation criteria in Annex I and Article 2 adaptation criteria in Annex II; the Regulation applies from 1 January 2022.
  2. Activity 8.1 (NACE J63.11) covers data storage, processing and transmission including edge computing; data centres include ICT, cooling, power, power distribution, building and monitoring systems.
  3. 8.1 is a transitional activity under Article 10(2) of the Taxonomy Regulation.
  4. Mitigation criterion 1: implement all relevant expected practices of the most recent EU Code of Conduct or CLC TR 50600-99-1, verified by an independent third party and audited at least every three years.
  5. Mitigation criterion 2: explain any expected practice that is not relevant; alternative practices with similar energy savings may replace it.
  6. Mitigation criterion 3: refrigerant GWP in the data centre cooling system must not exceed 675.
  7. Circular economy DNSH: equipment meets server and storage ecodesign requirements, complies with RoHS Annex II, a waste management plan ensures maximal recycling, and end-of-life equipment gets selective treatment per WEEE Annex VII.
  8. Adaptation (Annex II, 8.1): a climate risk and vulnerability assessment and adaptation solutions for material physical climate risks; highest-resolution projections for activities with more than 10 years' lifespan.
  9. The mitigation DNSH in Annex II 8.1 also requires all Code of Conduct expected practices assigned the maximum value of 5.
  10. Water DNSH (Appendix B) asks for an assessment aimed at good water status based on a water use and protection management plan; an EIA covering water impact removes the need for an extra assessment.

Using it in design

  • Assess EU Taxonomy section 8.1 using the Code of Conduct expected-practice checklist, justify non-applicable items and check the source’s refrigerant GWP limit of 675.
  • Keep ecodesign and RoHS flags on IT equipment in the catalogue; include an end-of-life waste management plan and WEEE Annex VII treatment among operating documents.
  • Screen site climate risks using Appendix A’s temperature, wind, water and solid-mass classes. Relate heat, flood and water-stress findings to adaptation and water DNSH assessments.
  • Use the GWP <= 675 limit as the first filter when selecting refrigerants in the cooling design.
  • Add the independent third-party verification and the at-least-three-year audit cycle to the operations calendar, since continued Taxonomy alignment depends on it.

Who should read it

Engineers, finance and sustainability teams assessing EU Taxonomy alignment of data centre investments, preparing sustainable finance disclosures or setting design criteria against this framework.

Document contents

  1. Recitals (1)-(59)
  2. Article 1: Mitigation criteria (Annex I)
  3. Article 2: Adaptation criteria (Annex II)
  4. Article 3: Entry into force and application
  5. Annex I: Technical screening criteria for climate change mitigation
  6. Annex I, 8. Information and communication
  7. Annex I, 8.1 Data processing, hosting and related activities
  8. Annex I, 8.2 Data-driven solutions for GHG emissions reductions
  9. Appendix A: Generic criteria for DNSH to climate change adaptation
  10. Appendix B: Generic criteria for DNSH to sustainable use and protection of water and marine resources
  11. Appendix C: Generic criteria for DNSH to pollution prevention and control regarding use and presence of chemicals
  12. Appendix D: Generic criteria for DNSH to protection and restoration of biodiversity and ecosystems
  13. Appendix E: Technical specifications for water appliances
  14. Annex II: Technical screening criteria for climate change adaptation
  15. Annex II, 8.1 Data processing, hosting and related activities

Related standards

  • Regulation (EU) 2020/852
  • CLC TR 50600-99-1
  • EU Code of Conduct Best Practices
  • Regulation (EU) 2019/424
  • Directive 2011/65/EU
  • Directive 2012/19/EU

Read the document

eu-taxonomy-climate-da-2021-2139.pdf

PDF · 2.8 MB · English

EU reuse (2011/833/EU): reuse permitted with acknowledgement of the source

The document is provided unaltered because its licence permits redistribution.

Publication details

Authors
European Commission
Publisher
European Commission
Year
2021
Document number
Delegated Regulation (EU) 2021/2139 (CELEX 32021R2139)
Document language
English
Source type
Government / public
Access
Open licence (downloadable)
Licence
EU reuse (2011/833/EU): reuse permitted with acknowledgement of the source
Licence evidence
eur-lex.europa.eu
Original licence note

Official Journal text (OJ L 442, 9.12.2021) downloaded from EUR-Lex; reuse authorised under Decision 2011/833/EU per the EUR-Lex legal notice.

Citation

European Commission (2021). Commission Delegated Regulation (EU) 2021/2139 of 4 June 2021 supplementing Regulation (EU) 2020/852 - EU Taxonomy Climate Delegated Act (incl. activity 8.1 Data processing, hosting and related activities). European Commission. Delegated Regulation (EU) 2021/2139 (CELEX 32021R2139). https://eur-lex.europa.eu/legal-content/EN/TXT/PDF/?uri=CELEX:32021R2139

All content and rights belong to the respective authors and publishers. SoSo CAD provides only the citation, its own summary and a link to the source, and is not responsible for the sources' content.

Cost studies in SoSo CAD

Calculate equipment cost, energy cost and total cost of ownership (TCO) from the design’s quantities and your own price assumptions.

CAPEX and TCO estimates in the SoSo CAD cost workspace

Keep your reading list current

Once a month: new library sources, changes to Turkish regulations and upcoming data centre events.