EMI Minimization from Stacked Radiation Sources by Means of Multiple Objective Genetic Algorithm

Electronics / MDPI · Riccardo Cecchetti, Francesco de Paulis et al.

A 2022 Electronics (MDPI) paper optimises the arrangement of nine server trays in a rack with a spherical wave expansion and a multi-objective genetic algorithm to reduce the external radiated field.

On this page

Overview

Containing unwanted electromagnetic radiation and interference is a relevant topic for the system design of any electrical system, and even more for data centres. The racks hosting piles of servers are among the main sources of electromagnetic noise. Such radiation can couple with other computing machines and with sensitive electronic devices needed to manage and maintain the centre.

The work aims to show that a proper stack-up of the trays in the rack reduces unwanted physical electromagnetic radiation. A multi-objective genetic algorithm based on the spherical wave expansion technique is developed; the model considers nine trays of three types in a rack and the optimiser searches tray positions using reconstructed external electromagnetic fields. The algorithm and its constraints are described and the results discussed. The study adds an electromagnetic constraint to rack-layout studies.

Key points

  1. In data centres racks are among the main sources of electromagnetic noise.
  2. The method is a spherical wave expansion with a multi-objective genetic algorithm.
  3. The model considers nine trays of three types in a rack.
  4. The optimiser searches tray positions using reconstructed external electromagnetic fields.
  5. The goal is to reduce the external radiated field through tray arrangement.

Using it in design

  • Evaluate in-rack equipment arrangement not only on thermal and power criteria but also on the position of high-emission devices.
  • Consider the placement of sensitive management and measurement devices beside and behind the rack together with radiation reduction results.
  • Add the electromagnetic constraint as an extra objective in rack layout optimisations.
  • Do not adopt the results as a design rule for your own server tray types without validation.

Who should read it

Engineers and researchers working on rack layout, electromagnetic compatibility and data-centre equipment placement.

Publication details

Authors
Riccardo Cecchetti; Francesco de Paulis; Carlo Olivieri; Antonio Orlandi
Publisher
Electronics / MDPI
Year
2022
Document language
English
Source type
Scientific
Access
Free to read
Licence
CC BY 4.0: share with attribution
Original licence note

Article-specific CC BY 4.0 notice verified on the publisher page. Retain attribution, license link and change notices; third-party exceptions require separate review. Generic MDPI dc.rights metadata may say BY 3.0; the article-specific notice takes precedence. Round 5/6 ingestion retains bibliographic metadata only; no local full text is redistributed.

Citation

Riccardo Cecchetti; Francesco de Paulis; Carlo Olivieri; Antonio Orlandi (2022). EMI Minimization from Stacked Radiation Sources by Means of Multiple Objective Genetic Algorithm. Electronics / MDPI. https://doi.org/10.3390/electronics11091402

All content and rights belong to the respective authors and publishers. SoSo CAD provides only the citation, its own summary and a link to the source, and is not responsible for the sources' content.

Power design in SoSo CAD

Calculate supply paths, equipment loads and UPS failure scenarios as part of the design.

Single-line diagram in the SoSo CAD power and capacity workspace

Keep your reading list current

Once a month: new library sources, changes to Turkish regulations and upcoming data centre events.