Data center waste heat for district heating networks: A review
Renewable and Sustainable Energy Reviews (Elsevier BV) · Xiaolei Yuan, Jiayi Liu et al.
A 2025 Renewable and Sustainable Energy Reviews paper reviews data-centre waste heat in district heating, covering technical, energy, economic and environmental aspects and four barrier groups.
On this page
Overview
The review evaluates integration of data-centre waste heat into district heating networks from four perspectives: technical, energy, economic and environmental. It covers global efforts to recover waste heat, existing research, practical applications and the effectiveness of current technologies.
The key challenges identified are complex technical issues, economic constraints, policy limitations and gaps in infrastructure. The study proposes solutions to these challenges, aiming to improve the efficiency and feasibility of waste heat recovery systems.
The future trends section highlights technological innovations such as smart energy systems and thermal energy storage as enablers of further progress. The goal is to give a detailed overview of the current landscape and offer actionable recommendations for integrating waste heat into district heating.
Key points
- Four perspectives are covered: technical, energy, economic and environmental.
- Global research and practical waste heat recovery projects are reviewed.
- Key barriers are technical complexity, economic constraints, policy limitations and infrastructure gaps.
- The study proposes solutions for each group of barriers.
- Thermal energy storage and smart energy systems are highlighted as future enablers of waste heat integration.
Using it in design
- Add a risk checklist with four barrier headings (technical, economic, policy, infrastructure) to heat export pre-feasibility.
- Reserve design provision for thermal storage to cover the timing mismatch between heat demand and waste heat output.
- Collect district heating connection point, temperature level and distance data at the site-selection stage.
Who should read it
Designers planning waste heat recovery, district heating operators and policy makers.
Related standards
- EN 50600-4-6 (ERF)
Publication details
- Authors
- Xiaolei Yuan; Jiayi Liu; Sijia Sun; Xiaojie Lin; Xiaojun Fan; Weixin Zhao; Risto Kosonen
- Publisher
- Renewable and Sustainable Energy Reviews (Elsevier BV)
- Year
- 2025
- Document language
- English
- Source type
- Scientific
- Access
- Free to read
- Licence
- CC BY 4.0: share with attribution
Original licence note
Publisher-deposited Crossref licence metadata: http://creativecommons.org/licenses/by/4.0/ (OpenAlex: cc-by); landing page blocks automated fetch, abstract read via Crossref/OpenAlex. Round 1 ingestion retains bibliographic metadata only; no local full text is redistributed.
Citation
Xiaolei Yuan; Jiayi Liu; Sijia Sun; Xiaojie Lin; Xiaojun Fan; Weixin Zhao; Risto Kosonen (2025). Data center waste heat for district heating networks: A review. Renewable and Sustainable Energy Reviews (Elsevier BV). https://doi.org/10.1016/j.rser.2025.115863
All content and rights belong to the respective authors and publishers. SoSo CAD provides only the citation, its own summary and a link to the source, and is not responsible for the sources' content.