Friterm Dry Coolers and Wet/Dry (Adiabatic) Cooler Systems for Industrial Process Cooling
Original title Endüstriyel Proses Soğutma İçin Kuru–Islak/Kuru Soğutucular
Friterm
Friterm brochure on dry coolers: direct water spray, Ecomesh mesh spray, fogging and pad (non-circulating and recirculating) adiabatic systems, with Eurovent-certified, capacity-guaranteed design.
On this page
Overview
The brochure introduces Friterm A.Ş., founded in Istanbul in 1979, and its finned-tube heat exchangers. With two plants in Tuzla and Dilovası totalling 51,000 m² of closed area and more than 350 staff, the company makes condensers, evaporators, dry coolers, air heaters and coolers, oil coolers and heat recovery coils. Its quality system is ISO 9001:2015 certified, and its coil design software FrtCoils 4.5 is certified under the Eurovent COIL programme; dry coolers are also certified in the Eurovent HE programme. Products are CE-marked and hold EAC certification for export to Russia and the CIS.
The main subject is dry coolers and wet/dry cooler systems for industrial process cooling. They are offered for process water plants in plastics, chemicals and energy, and as a free-cooling alternative in air conditioning systems at low outdoor temperature. Five adiabatic configurations are listed: direct water spray, Ecomesh mesh spray, fogging, non-circulating pad and recirculating pad.
The direct water spray system gives adiabatic cooling by intermittently spraying water into the incoming air stream and requires strict water treatment. The Ecomesh system sprays water intermittently onto a large mesh surface in front of the heat exchanger so the fins are not affected by calcareous water. Stated benefits: an alternative to cooling towers, no water loss to the atmosphere, no continuous make-up water, no Legionella risk, no fouling in the circuit thanks to the closed loop, low maintenance and operating cost, and energy savings through free cooling. The brochure has no numeric capacity or water consumption tables.
Key points
- Friterm was founded in 1979; 51,000 m² closed area at Tuzla and Dilovası and more than 350 staff.
- ISO 9001:2015 (TÜV-NORD); FrtCoils 4.5 software certified in Eurovent COIL and dry coolers in Eurovent HE.
- Products are CE-marked and EAC certified.
- Five adiabatic options: direct water spray, Ecomesh mesh spray, fogging, non-circulating pad, recirculating pad.
- The direct spray system needs strict water treatment.
- In the Ecomesh system fins are protected from calcareous water; there is no water loss to the atmosphere and no continuous make-up.
- Stated benefits: cooling tower alternative, no Legionella risk, closed circuit, low maintenance cost, free-cooling energy savings.
- Dry cooler design is capacity-guaranteed through software.
Using it in design
- For a data centre, compare dry cooler leaving water temperature in dry and adiabatic modes over the hottest hours of the year and extract the hours the adiabatic mode will run.
- Write water treatment and quality requirements for direct spray, and drainage and maintenance for Ecomesh and pad types, into the operating plan.
- When assessing the system as a cooling tower alternative, calculate closed-loop tightness and water consumption (adiabatic mode only).
- Ask for the software output and Eurovent certification scope for capacity in the specification.
- Add cleaning and scale management of pad and mesh surfaces to the maintenance schedule.
Who should read it
Mechanical designers comparing dry cooler and adiabatic cooling options.
Document contents
- Company introduction and certificates
- Dry coolers for industrial process cooling
- Wet/dry cooler systems
- Direct water spray
- Ecomesh mesh water spray
- Fogging and pad systems
- Advantages of the system
Publication details
- Authors
- Friterm
- Publisher
- Friterm
- Year
- Year not stated
- Document language
- Turkish
- Source type
- Manufacturer
- Access
- Free to read
- Licence
- Copyright retained; citation only: the publisher’s terms apply to the original document
Original licence note
Two-page bilingual manufacturer PDF recovered from current publisher storage. Original Turkish sections read. Undated; public access does not establish redistribution rights.
Citation
Friterm Endüstriyel Proses Soğutma İçin Kuru–Islak/Kuru Soğutucular. Friterm. https://friterm.com/storage/documents/01M0S8NZ22PCYAPJAF0M0W7KGE.pdf
All content and rights belong to the respective authors and publishers. SoSo CAD provides only the citation, its own summary and a link to the source, and is not responsible for the sources' content.