Giganet GN-IR-3PH-6012A 12 kW In-Row Cooling Datasheet, p.2
Original title Giganet GN-IR-3PH-6012A datasheet, p.2
Giganet
Giganet GN-IR-3PH-6012A is a 380 V 3-phase 12 kW class direct-expansion in-row cooling unit giving 11.5 kW total capacity at 35 °C/26% RH return air and 12.2 kW at 37 °C/24% RH.
On this page
Overview
The datasheet presents Giganet's 12 kW in-row cooling unit, part number GN-IR-3PH-6012A. It is a fully closed inner-loop, row-based cooling unit that can be used without a dedicated data-centre room. Listed features include a built-in rack monitoring unit, optional integration with UPS, distribution and wiring, a double-layer tempered glass door, a dustproof low-noise design and easy relocation. Physical data are 300/600 mm width, 1000-1200 mm depth and 2000 mm height.
The EVO control system shows running status and the temperature and humidity of inlet and outlet air on a graphic display and supports teamwork of up to 32 units; RS485 is standard, with SNMP, TCP/IP and GPRS with SMS optional. An electronic expansion valve, DC inverter compressor and EC fan let capacity match heat load closely. The maker states energy saving of 20% for the DC inverter against an AC inverter and 50% against a constant-speed compressor, and 30% for the EC fan against an AC fan; starting current is low.
The technical table has two return-air conditions: 35 °C/26% RH and 37 °C/24% RH. Sensible heat ratio is 100%, so total and sensible capacity are equal. Maximum power is 8.0 kW, full load current 16.5 A, one compressor (rated power 2.7 and 2.9 kW), 6 EC fans (0.35 kW, total 2500 m3/h), heating 3 kW and humidification 3.0 kg/h. Dimensions: 600 mm wide, 1200 mm deep, 2000 mm high. The outdoor unit GN-IR-C16 has 10.5 A full load current, 1280 x 360 x 1260 mm, 125 kg, a 20 A breaker and 2.5 mm2 cable; the -40 to 45 °C range is achieved with a low-temperature startup kit.
Key points
- Total and sensible capacity 11.5 kW (35 °C/26% RH) and 12.2 kW (37 °C/24% RH); sensible heat ratio 100%.
- 380 V 3-phase 50 Hz; maximum power 8.0 kW, full load current 16.5 A.
- One compressor, rated power 2.7 and 2.9 kW; 6 EC fans, 0.35 kW, 2500 m3/h.
- Heating 3 kW; humidification 3.0 kg/h.
- Gas line 28 and 19 mm, liquid line 16 and 12.7 mm; drain inside diameter 25 mm.
- Outdoor unit GN-IR-C16: 1280 x 360 x 1260 mm, 125 kg, full load current 10.5 A, 20 A breaker, 2.5 mm2 cable.
- DC inverter compressor, EC fans and electronic expansion valve; networking of up to 32 units.
Using it in design
- Use capacity with the return-air condition (35 °C/26% RH or 37 °C/24% RH); request curves from the maker if the room temperature differs.
- Use maximum power and full load current for UPS and panel sizing, and the outdoor-unit current as a separate feeder.
- Use gas and liquid line sizes in the indoor-to-outdoor pipe route and length check.
- Plan to manage in-row units in a contained-aisle layout on one network of up to 32 units and to connect to the BMS over RS485 or SNMP.
- Compare the outdoor unit's operating temperature range (including the low-temperature kit) with the site climate.
Who should read it
Mechanical designers selecting direct-expansion in-row cooling and planners of small and medium data halls.
Document contents
- Features
- Features of the Giganet in-row cooling unit (EVO control, electronic expansion valve, reliability, energy saving)
- Performance technical data
- Indoor EC fan data
- Heating and humidification
- Connection size and dimensions
- Outdoor unit technical data
Publication details
- Authors
- Giganet
- Publisher
- Giganet
- Year
- Year not stated
- Document language
- English
- Source type
- Manufacturer
- Access
- Free to read
- Licence
- Copyright retained; citation only: the publisher’s terms apply to the original document
Original licence note
No document-specific redistribution permission was established. Bibliographic reference only.
Citation
Giganet Giganet GN-IR-3PH-6012A datasheet, p.2. Giganet. https://www.giga-net.co.uk/_files/ugd/331712_b84fbc83dfcc45c0913dd5749d724bfa.pdf
All content and rights belong to the respective authors and publishers. SoSo CAD provides only the citation, its own summary and a link to the source, and is not responsible for the sources' content.
