Energy Efficiency of Servers
IEA 4E EDNA
The April 2025 IEA 4E EDNA study examines how server efficiency developed over the past decade: compound annual growth of 26% for general-purpose servers, 49% for accelerated computing chips and 47% for ASICs.
On this page
Overview
The study aims to show how the energy efficiency of servers, the main devices behind data-centre electricity demand, developed over the past decade. The publisher's page notes that trends such as cloud computing, video streaming, the Internet of Things and especially artificial intelligence and machine learning will keep increasing the data stored and processed in data centres, and that efficiency gains can partly offset the demand.
According to the page, efficiency is hard to assess because of the variety of hardware and workloads, the lack of standard methods and assumptions, inconsistent system boundaries, dependencies on physical and software components, and fast innovation cycles. The results separate general-purpose servers, accelerated computing chips (for FP16/BF16 data representations) and ASICs.
Key points
- Efficiency grows at a compound annual rate of 26% for general-purpose servers.
- For accelerated computing chips (FP16/BF16) the rate is 49%.
- Compound annual growth for ASICs is 47%.
- Factors that make assessment difficult: hardware and workload diversity, lack of standard methods, inconsistent system boundaries, and hardware and software dependencies.
- The publication date is 21 April 2025.
Using it in design
- In server refresh planning, use the different efficiency growth rates for general-purpose and accelerated hardware (26% and 47-49%) as separate assumptions.
- In capacity and power planning, allow for efficiency gains offsetting demand growth only partly.
- In server efficiency benchmarks, define the system boundary and workload type explicitly.
Who should read it
Data-centre planners and policy analysts assessing server and infrastructure efficiency.
Publication details
- Authors
- IEA 4E EDNA
- Publisher
- IEA 4E EDNA
- Year
- 2025
- Document language
- English
- Source type
- Government / public
- Access
- Citation only
- Licence
- Copyright retained; citation only: the publisher’s terms apply to the original document
Original licence note
Open publisher overview inspected; download click verified registration form. No account created or form submitted; full report and personal author list not verified.
Citation
IEA 4E EDNA (2025). Energy Efficiency of Servers. IEA 4E EDNA. https://www.iea-4e.org/publications/edna/energy-efficiency-of-servers/
All content and rights belong to the respective authors and publishers. SoSo CAD provides only the citation, its own summary and a link to the source, and is not responsible for the sources' content.