Low-voltage electrical installations - Part 4-44: Protection for safety - Protection against voltage disturbances and electromagnetic disturbances
IEC · IEC TC 64
The third edition of IEC 60364-4-44:2024 sets out installation safety against voltage and electromagnetic disturbances, including transient overvoltages and surge protection.
This document is sold by IEC and is available from the publisher’s site. SoSo CAD does not sell or distribute it; this page holds only catalogue details and our own summary.
On this page
Overview
The standard is Part 4-44 of the low-voltage electrical installations series prepared by IEC TC 64. It specifies requirements for the safety of installations in the event of voltage disturbances and electromagnetic disturbances. Its scope includes transient overvoltages and surge protective devices (SPDs). It is not intended for public energy distribution or for generation and transmission systems; it addresses the consumer installation only.
The third edition was published on 19 December 2024 and replaces the 2007 edition together with Amendment 1:2015 and Amendment 2:2018. The catalogue lists a 116-page redline version, and Amendment 1 is in preparation. It is a paid standard, and only the publisher's public catalogue abstract and product details were used here.
The edition makes structural changes: terms, definitions and symbols are regrouped in a new 440.3, and Clause 443 is amended to introduce DC SPDs. The change reflects the spread of installations with DC buses such as battery systems and photovoltaics. Related standards recorded include the IEC 61643 series, EN 50310 and IEC 62305. Limits: the full text was not read, so SPD placement rules, voltage classes and thresholds are absent from this record. For a data centre designer, the standard matters as the basis for the protection scheme against overvoltage and electromagnetic effects on critical IT loads.
Key points
- Specifies requirements for installation safety in the event of voltage and electromagnetic disturbances.
- Not intended for public energy distribution or generation and transmission systems.
- Third edition replaces the 2007 edition, Amendment 1:2015 and Amendment 2:2018.
- Terms, definitions and symbols are regrouped in the new 440.3.
- Clause 443 is amended to introduce DC SPDs.
- Published 2024-12-19; 116 pages (redline version); Amendment 1 in preparation.
- Related standards: IEC 61643 series, EN 50310, IEC 62305.
Using it in design
- In surge and EMC design, add an SPD placement rule set: origin of the installation, sub-distribution and sensitive IT boards, with DC SPDs for battery and PV DC buses.
- Run an earthing and bonding topology check for computer rooms (meshed bonding network).
- In specifications citing older editions, check the move to the 2024 edition and the DC SPD change in Clause 443.
- Consult the full text for exact placement distances and values.
Who should read it
Engineers designing electrical systems, surge protection and earthing for data centres.
Related standards
- IEC 61643 series
- EN 50310
- IEC 62305
Publication details
- Authors
- IEC TC 64
- Publisher
- IEC
- Year
- 2024
- Document number
- IEC 60364-4-44:2024
- Document language
- English
- Source type
- Standard
- Access
- Paid; available from the publisher
- Licence
- Copyright retained; citation only: the publisher’s terms apply to the original document
Original licence note
Paid standard. Record built only from the publisher's public catalogue abstract and product metadata; full text not redistributed.
Citation
IEC TC 64 (2024). Low-voltage electrical installations - Part 4-44: Protection for safety - Protection against voltage disturbances and electromagnetic disturbances. IEC. IEC 60364-4-44:2024. https://webstore.iec.ch/en/publication/104438
All content and rights belong to the respective authors and publishers. SoSo CAD provides only the citation, its own summary and a link to the source, and is not responsible for the sources' content.
