StandardPaid2012

Low-voltage switchgear and controlgear assemblies - Part 6: Busbar trunking systems (busways)

IEC · IEC TC 121

Product standard for low-voltage busbar trunking systems (busways), widely used for overhead rack power in data halls.

This document is sold by IEC and is available from the publisher’s site. SoSo CAD does not sell or distribute it; this page holds only catalogue details and our own summary.

On this page

Overview

IEC 61439-6 is the product part of the low-voltage switchgear and controlgear assemblies series devoted to busbar trunking systems (BTS, busways). It covers definitions, service conditions, construction requirements, technical characteristics and verification requirements for systems widely used for overhead rack power in data halls. It applies to BTS with a rated voltage not exceeding 1 000 V AC or 1 500 V DC.

Edition 1 was published on 23 May 2012, runs to 85 pages and cancels and replaces IEC 60439-2:2000 and its 2005 Amendment 1. It corrected inconsistencies in the resistance, reactance and impedance measurements and calculations. Edition 2 (IEC 61439-6:2026) is offered as an FDIS pre-release, with voting from 16 October to 27 November 2026, so the new edition is not yet in force.

Related documents are IEC 61439-1, IEC 60364-5-52 and TS EN 61439-6. The record gives no rated-current or withstand values; these must be taken from the manufacturer's catalogue and verification documents.

Key points

  1. Applies to BTS with rated voltage not exceeding 1 000 V AC or 1 500 V DC.
  2. Covers definitions, service conditions, construction, technical characteristics and verification requirements.
  3. Cancels and replaces IEC 60439-2:2000 and its Amendment 1 (2005).
  4. Corrected inconsistencies in resistance, reactance and impedance measurements and calculations.
  5. Edition 2 (IEC 61439-6:2026) offered as FDIS pre-release; voting 16 October to 27 November 2026.
  6. Edition 1 published 23 May 2012; 85 pages.
  7. Related standards: IEC 61439-1, IEC 60364-5-52, TS EN 61439-6.

Using it in design

  • In the busway object, catalogue rated current, Icw, R/X per metre, tap-off ratings and IP class.
  • Use the impedance data in the short-circuit and voltage-drop calculations.
  • Note the pending 2026 edition in the standards register.
  • Attach the manufacturer's verification documents for the selected BTS to the project file.

Who should read it

Electrical engineers selecting overhead busways and performing short-circuit and voltage-drop calculations.

Related standards

  • IEC 61439-1
  • IEC 60364-5-52
  • TS EN 61439-6

Publication details

Authors
IEC TC 121
Publisher
IEC
Year
2012
Document number
IEC 61439-6:2012
Document language
English
Source type
Standard
Access
Paid; available from the publisher
Licence
Copyright retained; citation only: the publisher’s terms apply to the original document
Original licence note

Paid standard. Record built only from the publisher's public catalogue abstract and product metadata; full text not redistributed.

Citation

IEC TC 121 (2012). Low-voltage switchgear and controlgear assemblies - Part 6: Busbar trunking systems (busways). IEC. IEC 61439-6:2012. https://webstore.iec.ch/en/publication/5463

All content and rights belong to the respective authors and publishers. SoSo CAD provides only the citation, its own summary and a link to the source, and is not responsible for the sources' content.

Power design in SoSo CAD

Calculate supply paths, equipment loads and UPS failure scenarios as part of the design.

Single-line diagram in the SoSo CAD power and capacity workspace

Keep your reading list current

Once a month: new library sources, changes to Turkish regulations and upcoming data centre events.