Technical guideFree to read2025

Cooling Systems: Scenario-Based System Solutions for Data Centers

Original title Soğutma Sistemleri: Veri Merkezleri İçin Senaryo Bazlı Sistem Çözümleri

İmbat

Imbat's September 2025 article presents two data center scenarios: dual-fluid precision air conditioning with chiller and dry cooler for N+1 or 2N, and a free cooling chiller for steady loads. Precision units span 6 to 150 kW.

On this page

Overview

The article describes how the Izmir-based HVAC manufacturer Imbat positions data center cooling as a system rather than separate products. Having all components from one brand, factory-tested and engineered to work together on site, is presented as reducing incompatibility risk and giving a single service point. The text is promotional and ties to the company's exhibition at ISK-Sodex Istanbul.

Scenario 1 is for critical sites needing uninterrupted operation. Single-circuit systems are said to fall short; the answer is a dual-fluid precision air conditioner with two separate liquid circuits, paired with a chiller and dry cooler. The precision unit controls temperature to ±1 °C and humidity to ±5%, and the dry cooler uses outdoor air to relieve the chiller. The arrangement is described as suitable for projects requiring N+1 or 2N redundancy.

Scenario 2 is for energy efficiency. For facilities with a steady heat load, a water-cooled precision unit works with a free cooling chiller that switches mechanical cooling off when outdoor conditions allow. The article says this improves PUE and extends equipment life, but gives no numeric PUE.

The same page also presents the precision air-conditioning series (6 to 150 kW, R410A or R454B, EC fans, electronic expansion valves, 0.83 to 1 sensible heat ratio) and the single-unit Perseus Rooftop series (60 to 360 kW, 3,850 to 55,200 m³/h) as an alternative to AHU plus chiller or VRF. The figures are manufacturer claims.

Key points

  1. Scenario 1: dual-fluid precision air conditioner with chiller and dry cooler; two separate liquid circuits targeting N+1 or 2N redundancy.
  2. Precision control holds ±1 °C temperature and ±5% humidity.
  3. Scenario 2: water-cooled precision unit with a free cooling chiller that disables mechanical cooling when ambient allows; recommended for steady heat loads.
  4. The Imbat precision series spans 6 kW to 150 kW, uses R410A or R454B, and has EC fans and electronic expansion valves.
  5. Sensible heat ratio is 0.83 to 1; cooling, heating, humidification and dehumidification are integrated in one unit.
  6. Perseus Rooftop: 60 to 360 kW cooling and 3,850 to 55,200 m³/h airflow; R454B is stated to have 78% lower environmental impact than R410A.
  7. Perseus uses a double-skin casing with 50 mm A1-class rock wool panels at 70 kg/m³; thermodynamic heat recovery is claimed to save up to 30% energy.
  8. According to the article, AHU plus chiller or AHU plus VRF layouts have many components, causing high first cost and difficult commissioning.

Using it in design

  • For an N+1 or 2N target, compare a dual-circuit precision unit with chiller and dry cooler against a single-circuit alternative on redundancy and maintainability.
  • For steady, low-variability loads, compute annual free cooling hours for a free cooling chiller from local climate data; the article's PUE improvement is not quantified, so do your own calculation.
  • In precision unit selection, specify the ±1 °C and ±5% humidity control band, sensible heat ratio (0.83 to 1) and refrigerant type (R410A or R454B).
  • Compare a single-brand integrated solution with a multi-vendor one on commissioning time, service point and compatibility risk.
  • Have manufacturer efficiency and saving claims confirmed by independent testing or site measurement.

Who should read it

Mechanical designers and procurement teams selecting cooling for small and mid-sized data centers and server rooms in Turkey.

Document contents

  1. Data center cooling: a system approach, not just equipment
  2. Scenario 1: need for uninterrupted operation
  3. Scenario 2: need for energy efficiency
  4. One brand, one solution
  5. AHU + chiller / VRF configurations and the rooftop alternative
  6. Perseus Rooftop

Publication details

Authors
İmbat
Publisher
İmbat
Year
2025
Document language
Turkish
Source type
Manufacturer
Access
Free to read
Licence
Copyright retained; citation only: the publisher’s terms apply to the original document
Original licence note

Üreticinin herkese açık kaynağı okundu. Açık erişim yeniden dağıtım izni değildir; tam metin kütüphaneye alınmaz. Sayfa tarihi 5 Eylül 2025. Açık PDF kılavuz bulunamadı; kaynağın kendisi sayfasız HTML olduğundan where alanları bölüm başlığını belirtir.

Citation

İmbat (2025). Soğutma Sistemleri: Veri Merkezleri İçin Senaryo Bazlı Sistem Çözümleri. İmbat. https://imbat.com/tr/sogutma-sistemleri/

All content and rights belong to the respective authors and publishers. SoSo CAD provides only the citation, its own summary and a link to the source, and is not responsible for the sources' content.

Cooling capacity in SoSo CAD

Check zone heat loads, installed capacity and the capacity left with the largest unit out, as part of the design.

Zone heat loads and capacity balance in the SoSo CAD cooling workspace

Keep your reading list current

Once a month: new library sources, changes to Turkish regulations and upcoming data centre events.