Recommendation ITU-T L.1305 (11/2019): Data centre infrastructure management system based on big data and artificial intelligence technology
International Telecommunication Union (ITU-T) · ITU-T Study Group 5
ITU-T L.1305 (11/2019) is an in-force recommendation specifying a DCIM system: principles, managed objects, data collection, energy-saving and capacity management, and AI control of cooling.
On this page
Overview
ITU-T L.1305 is an in-force recommendation dated November 2019. For a data-centre infrastructure management system (DCIM) based on big data and artificial intelligence, it covers principles, management objects, system schemes, data collection and operational function requirements.
It includes capacity management for both ICT and facility infrastructure. It also describes full-stack digital maintenance: availability management, maintenance process, shift management and a maintenance knowledge library. It sets principles for AI services applied to the cooling system, with the aim of maximising green energy use.
During design it provides a functional checklist to use when specifying DCIM.
Key points
- ITU-T recommendation dated November 2019, in force.
- Covers managed objects, system schemes, data collection and operational function requirements.
- Includes capacity management for ICT and facility infrastructure.
- Full-stack digital maintenance: availability management, maintenance process, shift management and a knowledge library.
- Defines principles for AI services applied to the cooling system.
Using it in design
- Turn the DCIM specification into a checklist built on this recommendation's functional headings.
- Write capacity-management requirements that cover both IT and facility sides.
- If AI control of cooling is wanted, define data-collection and principle requirements by reference to this recommendation.
- Add maintenance process, shift and knowledge-library functions explicitly to the DCIM scope.
Who should read it
Design engineers writing DCIM specifications and operations teams selecting monitoring and maintenance systems.
Related standards
- ITU-T L.1301
Publication details
- Authors
- ITU-T Study Group 5
- Publisher
- International Telecommunication Union (ITU-T)
- Year
- 2019
- Document number
- ITU-T L.1305 (11/2019)
- Document language
- English
- Source type
- Expert / community
- Access
- Free to read
- Licence
- Copyright retained; citation only: the publisher’s terms apply to the original document
Original licence note
ITU Recommendation, (c) ITU, all rights reserved; English PDF downloadable free of charge.
Citation
ITU-T Study Group 5 (2019). Recommendation ITU-T L.1305 (11/2019): Data centre infrastructure management system based on big data and artificial intelligence technology. International Telecommunication Union (ITU-T). ITU-T L.1305 (11/2019). https://www.itu.int/rec/T-REC-L.1305
All content and rights belong to the respective authors and publishers. SoSo CAD provides only the citation, its own summary and a link to the source, and is not responsible for the sources' content.