IT Equipment Energy Assessment Tool (IT Efficiency Tool), Version 2.5 (October 2023)

Lawrence Berkeley National Laboratory, Center of Expertise for Energy Efficiency in Data Centers · Lawrence Berkeley National Laboratory

The DOE's Excel-based tool, maintained by Lawrence Berkeley National Laboratory, that identifies savings from upgrades of server, storage and network equipment.

On this page

Overview

The IT Efficiency Tool is an Excel-based tool of the US Department of Energy (DOE), maintained by the Lawrence Berkeley National Laboratory (LBNL) Center of Expertise for Energy Efficiency in Data Centers. It is used to identify the savings that can be achieved by upgrading IT equipment, meaning servers, storage and network devices. The resource page is freely accessible, and the tool is distributed as an Excel file with a user manual (Version 2.5, 27 October 2023).

Citing the Uptime Institute (2020), the resource page states that many IT efficiency opportunities in servers, network and storage remain untapped. The tool's purpose is to make those opportunities measurable. It acts as a counterweight to efficiency work that focuses mostly on cooling and power infrastructure while overlooking the IT equipment itself. The November 2023 version brought two notable changes. The first is that on-site water savings can be calculated using the WUE metric. The second is improved interoperability among the IT Equipment, Air Management and Electrical Power Chain system tools. As a result, the knock-on effect of an IT refresh on cooling and power losses can be followed within a single tool family.

The tool is a resource and calculator rather than an independent standard or regulation, and its results depend on the quality of the input data. ISO/IEC 30134-9 (WUE) is named as the related standard.

Key points

  1. The DOE's Excel-based IT Efficiency Tool is maintained by the LBNL Center of Expertise.
  2. It identifies savings from server, storage and network equipment upgrades.
  3. The November 2023 version added on-site water savings using the WUE metric.
  4. Interoperability among the IT Equipment, Air Management and Electrical Power Chain tools was improved.
  5. Distributed as an Excel tool with a user manual (Version 2.5, 10-27-2023).
  6. The page cites Uptime Institute (2020) that many IT efficiency opportunities remain untapped.
  7. Related standard: ISO/IEC 30134-9 (WUE).

Using it in design

  • In IT-refresh scenarios, propagate savings through cooling losses, power losses and water (WUE), as the DOE tool suite does.
  • Use matching input definitions and system boundaries when cross-checking results against the DOE calculations.
  • Model server, storage and network refreshes as separate items.
  • Report water savings through WUE and use definitions consistent with ISO/IEC 30134-9.

Who should read it

Data centre engineers and energy managers assessing the energy and water impact of IT equipment refresh scenarios.

Related standards

  • ISO/IEC 30134-9 (WUE)

Publication details

Authors
Lawrence Berkeley National Laboratory
Publisher
Lawrence Berkeley National Laboratory, Center of Expertise for Energy Efficiency in Data Centers
Year
2023
Document number
Version 2.5
Document language
English
Source type
Government / public
Access
Free to read
Licence
Copyright retained; citation only: the publisher’s terms apply to the original document
Original licence note

LBNL (contractor-operated DOE laboratory) resource; not US-Gov public domain. Cited only.

Citation

Lawrence Berkeley National Laboratory (2023). IT Equipment Energy Assessment Tool (IT Efficiency Tool), Version 2.5 (October 2023). Lawrence Berkeley National Laboratory, Center of Expertise for Energy Efficiency in Data Centers. Version 2.5. https://datacenters.lbl.gov/resources/it-efficiency-assessment-tool

All content and rights belong to the respective authors and publishers. SoSo CAD provides only the citation, its own summary and a link to the source, and is not responsible for the sources' content.

Cost studies in SoSo CAD

Calculate equipment cost, energy cost and total cost of ownership (TCO) from the design’s quantities and your own price assumptions.

CAPEX and TCO estimates in the SoSo CAD cost workspace

Keep your reading list current

Once a month: new library sources, changes to Turkish regulations and upcoming data centre events.