The NIST Definition of Cloud Computing
Original title NIST SP 800-145: The NIST Definition of Cloud Computing
National Institute of Standards and Technology · Peter Mell, Timothy Grance
A three-page NIST publication that defines cloud computing through five essential characteristics, three service models and four deployment models. It gives a shared vocabulary for comparing cloud services and deployment strategies.
U.S. public domain: U.S. Government work; free to reuse
On this page
Overview
Published in September 2011 by Peter Mell and Timothy Grance of the NIST Computer Security Division, the document was prepared for federal agencies but may be used voluntarily by other organisations and is not subject to copyright. Its purpose is to support broad comparisons of cloud services and deployment strategies and to give a baseline for discussion, from what cloud computing is to how best to use it. The service and deployment models form a simple taxonomy that does not prescribe any method of deployment, delivery or business operation.
The definition describes cloud computing as a model for ubiquitous, convenient, on-demand network access to a shared pool of configurable resources (networks, servers, storage, applications, services) that can be rapidly provisioned and released with minimal management effort. The five essential characteristics are on-demand self-service, broad network access, resource pooling (a multi-tenant model), rapid elasticity and measured service.
Three service models are defined: SaaS, where the consumer uses the provider's applications; PaaS, where the consumer deploys its own or acquired applications using the provider's tools; and IaaS, where the consumer provisions processing, storage and networks and runs arbitrary software. The four deployment models are private, community, public and hybrid clouds. A footnote splits cloud infrastructure into a physical layer of server, storage and network hardware and an abstraction layer of software above it.
Key points
- The cloud model has five essential characteristics, three service models and four deployment models.
- The five characteristics are on-demand self-service, broad network access, resource pooling, rapid elasticity and measured service.
- With resource pooling the customer generally does not know the exact location of resources but may specify it at a higher level such as country, state or datacenter.
- Measured service is typically on a pay-per-use or charge-per-use basis.
- In SaaS the consumer does not manage the infrastructure; in PaaS it controls deployed applications and possibly hosting-environment settings; in IaaS it controls operating systems, storage and deployed applications.
- A private cloud is for a single organisation and may be on or off premises; a public cloud exists on the provider's premises.
- A community cloud serves a community with shared concerns such as mission, security requirements, policy and compliance.
- A hybrid cloud binds two or more distinct clouds with technology that enables data and application portability, for example cloud bursting.
Using it in design
- Use the NIST terms when describing on-prem and SaaS delivery of the platform: an on-prem installation is a private cloud, a hosted service is SaaS.
- In data-centre capacity planning, state the customer-facing service model (IaaS, PaaS, SaaS), because the layer the provider manages, and so the facility's responsibility, differs in each.
- Treat resource pooling and rapid elasticity as inputs to demand variability when sizing power and cooling shares together with redundancy.
- Record private or community cloud as a separate facility requirement for customers with location or confidentiality needs, distinct from public cloud.
Who should read it
System planners, programme managers and technologists adopting cloud computing as consumers or providers.
Document contents
- 1. Introduction
- 1.1 Authority
- 1.2 Purpose and Scope
- 1.3 Audience
- 2. The NIST Definition of Cloud Computing
- Essential Characteristics
- Service Models
- Deployment Models
Read the document
nist-sp-800-145-cloud-definition.pdf
U.S. public domain: U.S. Government work; free to reuse
The document is provided unaltered because its licence permits redistribution.
Publication details
- Authors
- Peter Mell; Timothy Grance
- Publisher
- National Institute of Standards and Technology
- Year
- 2011
- Document number
- NIST SP 800-145
- Document language
- English
- Source type
- Expert / community
- Access
- Open licence (downloadable)
- Licence
- U.S. public domain: U.S. Government work; free to reuse
- Licence evidence
- www.copyright.gov
Original licence note
NIST publication available free of charge via doi.org/10.6028; the front-matter authority/copyright statement says it is not subject to copyright in the United States (attribution appreciated); U.S. government work under 17 U.S.C. 105.
Citation
Peter Mell; Timothy Grance (2011). NIST SP 800-145: The NIST Definition of Cloud Computing. National Institute of Standards and Technology. NIST SP 800-145. https://doi.org/10.6028/NIST.SP.800-145
All content and rights belong to the respective authors and publishers. SoSo CAD provides only the citation, its own summary and a link to the source, and is not responsible for the sources' content.