LG Energy Solution UPS Backup Solution Technical Specifications (Grid/C&I Battery Product Info)
Original title LG Energy Solution UPS Backup Solution technical specifications
LG Energy Solution
LG Energy Solution's UPS backup rack M4864P6B holds 10 packs for 33.0 kWh, 115 kW continuous power and a 420 to 588 V range; the second rack, M48128P6B, offers 65.9 kWh.
On this page
Overview
LG Energy Solution's Grid/C&I battery product page lists 11 products: grid-scale and C&I (7) and stand-alone/UPS (4). Products are grouped as long duration and energy (5), short duration and power (2), telecom backup / residential pack (2) and UPS backup solution (2). For UPS applications there are two rack systems: the 10-pack M4864P6B and M48128P6B.
The M4864P6B rack has 33.0 kWh of energy, 115 kW continuous power, 515 V nominal voltage and a 420 to 588 V range. Dimensions are 600 x 2,000 x 650 mm (W x H x D) and weight is 390 kg. The M48128P6B rack holds 65.9 kWh and measures 600 x 2,000 x 800 mm. For these two racks the page links to spec sheet, warranty, certification, compatible inverters, installation and manual.
The same page lists grid-scale racks for comparison: R1000 (17 packs) at 126.6 to 253.2 kWh and 714 to 1,000 V, R1500 (24 packs) at 357.5 kWh and 1,008 to 1,411 V, and TR1300 at 327.7 kWh and 924 to 1,293.6 V. Short-duration power products are 56 and 112.1 kWh. The document is a manufacturer product-list page; it carries no cell chemistry, life or fire-safety information.
Key points
- UPS backup solution: two racks, M4864P6B (33.0 kWh) and M48128P6B (65.9 kWh), each of 10 packs.
- M4864P6B: 115 kW continuous power, 515 V nominal, 420 to 588 V range, 600 x 2,000 x 650 mm, 390 kg.
- M48128P6B: 600 x 2,000 x 800 mm, 420 to 588 V range.
- Grid-scale R1000 (17 packs): 126.6, 189.9 and 253.2 kWh; 714 to 1,000 V.
- R1500 (24 packs): 357.5 kWh; 1,008 to 1,411 V.
- TR1300: 327.712 kWh; 924 to 1,293.6 V; 1040 x 1200 x 1745 mm.
- Short-duration power products: 56 kWh (425 mm depth) and 112.1 kWh (655 mm).
- Telecom backup / residential packs: 6.5 kWh and 3.3 kWh, 42.0 to 58.8 V.
Using it in design
- Match the UPS DC bus voltage to the rack's 420 to 588 V range; check the 515 V nominal against the inverter input.
- Judge the 115 kW continuous power with the backup time: 33.0 kWh covers a short time at full power, so derive duration from the load profile.
- At 390 kg on a 600 x 650 mm footprint, check floor loading and seismic anchoring.
- Add the manufacturer's spec sheet, compatible inverter list and certificates to the specification.
Who should read it
Data-centre electrical designers evaluating lithium-ion battery racks for UPS systems.
Document contents
- Product info
- Long duration and energy
- Short duration and power
- Telecom backup solution / residential pack
- UPS backup solution
Publication details
- Authors
- LG Energy Solution
- Publisher
- LG Energy Solution
- Year
- Year not stated
- Document language
- English
- Source type
- Manufacturer
- Access
- Free to read
- Licence
- Copyright retained; citation only: the publisher’s terms apply to the original document
Original licence note
No document-specific redistribution permission was established. Bibliographic reference only.
Citation
LG Energy Solution LG Energy Solution UPS Backup Solution technical specifications. LG Energy Solution. https://www.lgessbattery.com/eu/grid/product-info.lg
All content and rights belong to the respective authors and publishers. SoSo CAD provides only the citation, its own summary and a link to the source, and is not responsible for the sources' content.