LG Energy Solution Global ESS Catalogue: UPS Backup Solution
Original title Global ESS catalogue: UPS backup solution
LG Energy Solution
The UPS rack section of LG Energy Solution's ESS catalogue lists three lithium-ion rack models (M7830P7B, M4864P6B, M48128P6B) with 28.0 to 65.9 kWh, 115-250 kW continuous power and 390-625 kg weight.
On this page
Overview
The document is LG Energy Solution's global catalogue of energy storage (ESS) products, covering grid-scale, home, commercial and industrial (C&I) and UPS applications. Shared technology points are the L&S (lamination and stacking) cell structure and the SRS separator with ceramic nano-particle coating. The catalogue shows a portfolio from cell to pack, rack and enclosure, and more than 14.8 GWh of grid-scale references as of December 2020.
The UPS backup section tabulates three rack models. M7830P7B: 28.0 kWh, 250 kW continuous, 466 V nominal (397-523 V range), 520 x 2,292 x 500 mm, 480 kg. M4864P6B: 33.0 kWh, 115 kW, 515 V nominal (420-588 V), 600 x 2,000 x 650 mm, 390 kg. M48128P6B: 65.9 kWh, 132 kW, 515 V (420-588 V), 600 x 2,000 x 800 mm, 625 kg. Dimensions are given as W x H x D.
The section provides energy, power, voltage window, size and weight for UPS racks; cycle life, warranty and fire protection installation requirements are not presented there. The catalogue dates from 2021 with reference data up to December 2020, so current product data should be requested from the manufacturer.
Key points
- UPS rack models: M7830P7B, M4864P6B and M48128P6B.
- Energy: 28.0 / 33.0 / 65.9 kWh; continuous power: 250 / 115 / 132 kW.
- Nominal voltage 466 V (397-523 V) and 515 V (420-588 V).
- Dimensions (W x H x D): 520 x 2,292 x 500, 600 x 2,000 x 650 and 600 x 2,000 x 800 mm.
- Weights 480, 390 and 625 kg.
- M7830P7B has the highest power density (250 kW from 28.0 kWh), suited to high-power, short-duration duty.
- LG Energy Solution states more than 14 GWh of grid-scale projects installed or awarded since starting its ESS business (December 2020).
Using it in design
- Compare the UPS DC bus voltage window with the rack voltage range (397-523 V or 420-588 V).
- Check the rack's kW and kWh balance against target autonomy using runtime = energy / power.
- Calculate floor loading from rack weight (390-625 kg) and footprint.
- Request the current datasheet from the manufacturer for up-to-date data and fire protection requirements.
Who should read it
Electrical designers and procurement teams evaluating lithium-ion UPS batteries.
Document contents
- Introduction
- ESS Solutions (Grid-scale, Home, C&I, UPS)
- Specifications
- Global Reference
Publication details
- Authors
- LG Energy Solution
- Publisher
- LG Energy Solution
- Year
- Year not stated
- Document language
- English
- Source type
- Manufacturer
- Access
- Free to read
- Licence
- Copyright retained; citation only: the publisher’s terms apply to the original document
Original licence note
No document-specific redistribution permission was established. Bibliographic reference only.
Citation
LG Energy Solution Global ESS catalogue: UPS backup solution. LG Energy Solution. https://www.lgessbattery.com/ImageServlet?imageType=CATALOGUE&imgPath=210319_LG_Energy_Solution_Catalogue_%28Global%29.pdf
All content and rights belong to the respective authors and publishers. SoSo CAD provides only the citation, its own summary and a link to the source, and is not responsible for the sources' content.