Technical guideFree to readYear not stated

Galaxy PX 300–600 kW IEC Technical Specifications 990-92422A-001: Model List, Specifications, Efficiency and Physical

Original title Galaxy PX 300–600 kW IEC technical specifications 990-92422A-001; Model List, Specifications, Efficiency and Physical

Schneider Electric

The Schneider Electric Galaxy PX 380/400/415 V 300-600 kW UPS technical specification (990-92422A-001, updated 09/2026) gives load-point efficiency tables for normal, ECO, eConversion and battery operation, with net and shipping dimensions.

On this page

Overview

The document is the technical specification for the Schneider Electric Galaxy PX 300-600 kW, 380/400/415 V UPS family (990-92422A-001; updated 09/2026). It covers the model list, single and parallel system overviews, input voltage window, inverter short-circuit capability (bypass not available), efficiency, derating by load power factor and battery end-of-discharge voltages.

The specifications are given separately for the 300, 400, 500 and 600 kW models. Alongside them are required upstream protection, recommended cable sizes, load sharing in a parallel system, bolt and lug sizes, torque values, UPS weights and dimensions, clearances and heat dissipation in BTU/hr. Efficiency is tabulated at stated load points for normal mode, ECO, eConversion and battery operation.

The options section lists weights and dimensions, with shipping values separately, for the Galaxy lithium-ion battery cabinet, classic battery cabinet, empty battery cabinet, battery circuit-breaker box and kit, and maintenance bypass cabinet. Requirements for third-party battery solutions and guidance on battery cable organisation are included. Rating and enclosure data depend on the exact product configuration, and efficiency statements without stated load points are not a part-load curve.

Key points

  1. Family covers 300-600 kW at 380/400/415 V, with separate specification tables for 300, 400, 500 and 600 kW.
  2. Efficiency is given at stated load points for normal mode, ECO, eConversion and battery operation.
  3. Inverter short-circuit capability (bypass not available) has its own section.
  4. Upstream protection, cable sizes, bolt and lug sizes and torque values are provided.
  5. UPS net and shipping weights and dimensions are listed separately, with clearances and heat dissipation in BTU/hr.
  6. Options include lithium-ion and classic battery cabinets, battery circuit-breaker box and kit, and a maintenance bypass cabinet.

Using it in design

  • Weights and dimensions change with configuration, so use the table for the exact configuration in floor-loading and layout plans.
  • Read efficiency only from tables with stated load points and separate heat-load and PUE calculations by operating mode (normal, ECO, eConversion).
  • Feed the upstream protection and cable tables into cable and switchgear selection, and the inverter short-circuit value into selectivity studies.
  • If a third-party battery is used, add the document's battery breaker and cable-layout requirements to the specification.

Who should read it

Electrical designers selecting large UPS systems, and engineers handling installation and switchgear coordination.

Publication details

Authors
Schneider Electric
Publisher
Schneider Electric
Year
Year not stated
Document number
990-92422A-001
Document language
English
Source type
Manufacturer
Access
Free to read
Licence
Copyright retained; citation only: the publisher’s terms apply to the original document
Original licence note

No document-specific redistribution permission was established. Bibliographic reference only.

Citation

Schneider Electric Galaxy PX 300–600 kW IEC technical specifications 990-92422A-001; Model List, Specifications, Efficiency and Physical. Schneider Electric. 990-92422A-001. https://productinfo.se.com/galaxypx_iec/990-99242-galaxy-px-300-600-kw-technical-specifications/English/990-99242%20Technical%20Specifications%20Galaxy%20PX%20300-600%20kW_DD01430087.xml

All content and rights belong to the respective authors and publishers. SoSo CAD provides only the citation, its own summary and a link to the source, and is not responsible for the sources' content.

Power design in SoSo CAD

Calculate supply paths, equipment loads and UPS failure scenarios as part of the design.

Single-line diagram in the SoSo CAD power and capacity workspace

Keep your reading list current

Once a month: new library sources, changes to Turkish regulations and upcoming data centre events.