Galaxy VXL 500–1250 kW 380/400/415 V Technical Specifications, 990-55333B-001: Model List, Specifications and Physical

Original title Galaxy VXL 500–1250 kW 380/400/415 V Technical Specifications, 990-55333B-001; Model List, Specifications and Physical

Schneider Electric

The Schneider Electric Galaxy VXL 500-1250 kW, 380/400/415 V technical specification (990-55333B-001) gives protection interfaces, net weights and battery options for scalable configurations and the non-scalable 600 kW model.

On this page

Overview

The document is an installation-facing technical specification for the 380/400/415 V Galaxy VXL UPS family from 500 to 1250 kW (990-55333B-001). Its headings are model list, specifications and physical data.

It covers the scalable Galaxy VXL configurations and the non-scalable 600 kW model. Protection interfaces, net weights and battery options are presented as data for installation planning.

Rating and enclosure data depend on the exact product configuration. Efficiency statements without stated load points do not form a part-load curve, so load-point tables should be used for efficiency calculations.

Key points

  1. Scope: Galaxy VXL, 500-1250 kW, 380/400/415 V.
  2. Scalable configurations and the non-scalable 600 kW model are treated separately.
  3. Protection interfaces and net weights are given as installation data.
  4. Battery options are included in the document.
  5. Rating and enclosure data depend on the exact configuration.

Using it in design

  • Use configuration-specific net weights for floor loading and layout.
  • Use the protection interface data as input to upstream and downstream protection selection.
  • Compare the scalable models and the 600 kW non-scalable model against your growth plan.
  • When selecting a battery option, take cabinet weight and dimensions from the document.

Who should read it

Electrical designers selecting large UPS systems and installation engineers.

Publication details

Authors
Schneider Electric
Publisher
Schneider Electric
Year
Year not stated
Document number
990-55333B-001
Document language
English
Source type
Manufacturer
Access
Free to read
Licence
Copyright retained; citation only: the publisher’s terms apply to the original document
Original licence note

No document-specific redistribution permission was established. Bibliographic reference only.

Citation

Schneider Electric Galaxy VXL 500–1250 kW 380/400/415 V Technical Specifications, 990-55333B-001; Model List, Specifications and Physical. Schneider Electric. 990-55333B-001. https://www.productinfo.schneider-electric.com/galaxyvxl_iec/990-990-55333-galaxy-vxl-380-400-415-v-technical-specifications/English/990-55333B_EN.pdf

All content and rights belong to the respective authors and publishers. SoSo CAD provides only the citation, its own summary and a link to the source, and is not responsible for the sources' content.

Power design in SoSo CAD

Calculate supply paths, equipment loads and UPS failure scenarios as part of the design.

Single-line diagram in the SoSo CAD power and capacity workspace

Keep your reading list current

Once a month: new library sources, changes to Turkish regulations and upcoming data centre events.