MPOWERSYS Tower Online UPS SMART Series Technical Table
Original title MPOWERSYS tower online UPS SMART series technical table
MPOWERSYS
The MPOWERSYS SMART series is a 1 to 10 kVA single-phase online double-conversion tower UPS with input power factor of at least 0.99, efficiency of 92 to 94% and 0 ms transfer time.
On this page
Overview
The MPOWERSYS SMART series is a small-capacity family of tower-type online double-conversion UPS units. There are five models: SMART-1001 (1 kVA), 1002 (2 kVA), 1003 (3 kVA), 1005 (5 kVA) and 1010 (10 kVA). Input voltage is 160 to 295 V, frequency 50/60 Hz ±5%, input is single-phase two-wire and input power factor is at least 0.99. Output voltage is 220 or 230 V ±1% and output THD is below 3% on linear load.
The page lists a wide input voltage range, hot-swappable batteries, over-current, short-circuit and overload protection, an EMI/RFI filter, ECO and EPO functions, external battery and cabinet options, RS-232/422/USB ports (SNMP and RS485 optional) and a 0 ms transfer time. Efficiency is 92 to 94% and the power factor is 0.99. Listed applications are data centres, retail, hubs, network devices, routers, precision equipment and commercial facilities.
Output power is given as 1000 VA / 900 W, 2000 / 1800, 3000 / 2700, 5000 / 4800 and 10000 / 8000 W, with output power factor of 0.8 to 0.9. Battery voltage is 24/36, 48/72, 72/96 or 192 V and backup time is selectable, for example 10, 30 or 60 minutes. Noise is 50 to 60 dB, operating temperature -5 to 40 °C and humidity 0 to 95%. Weight ranges from 7 to 70 kg. The document is the product page's feature and dimension table.
Key points
- Five models: 1, 2, 3, 5, 10 kVA (SMART-1001 to SMART-1010).
- Input 160 to 295 V, 50/60 Hz ±5%, single-phase; input power factor ≥0.99.
- Output 220 or 230 V ±1%; THD <3% (linear load); transfer time 0 ms.
- Output power: 1000/900, 2000/1800, 3000/2700, 5000/4800, 10000/8000 VA/W.
- Efficiency 92 to 94%; ECO and EPO functions; hot-swappable battery.
- Battery voltage 24/36, 48/72, 72/96 or 192 V; backup time selectable at 10, 30, 60 minutes.
- Communication RS-232, 422, USB; SNMP, RS485 and dry contact optional.
- Operation -5 to 40 °C, humidity 0 to 95%; noise 50 to 60 dB.
Using it in design
- On the 10 kVA model, note that active power is 8000 W; select by kW.
- The input range down to 160 V reduces battery use at sites with weak mains.
- Match battery voltage (24 to 192 V) to model capacity and state the backup time at order stage.
- For network and office use, add the SNMP option to the specification along with the monitoring requirement.
- Use ECO mode on non-critical loads to raise efficiency and keep it off for sensitive loads.
Who should read it
Engineers selecting tower UPS units for small server rooms and network equipment.
Document contents
- Product features
- Electrical characteristics
- Dimensions and weight
Publication details
- Authors
- MPOWERSYS
- Publisher
- MPOWERSYS
- Year
- Year not stated
- Document language
- Korean
- Source type
- Manufacturer
- Access
- Free to read
- Licence
- Copyright retained; citation only: the publisher’s terms apply to the original document
Original licence note
No document-specific redistribution permission was established. Bibliographic reference only. Original publisher HTTP URL retained as a bibliographic link. Its HTTPS counterpart could not be verified on 2026-11-16; no content was downloaded or redistributed.
Citation
MPOWERSYS MPOWERSYS tower online UPS SMART series technical table. MPOWERSYS. http://www.mpowersys.co.kr/bbs/page.php?hid=ups_tower
All content and rights belong to the respective authors and publishers. SoSo CAD provides only the citation, its own summary and a link to the source, and is not responsible for the sources' content.