REVO 3.0 TPX600 at Data Centre World Asia 2025

Vision

Vision Battery showed the REVO 3.0 TPX600 LFP UPS battery cabinet at DCWA 2025, rated 600 kW per cabinet; two cabinets reach 1.2 MW of UPS capacity with 80% less footprint and 30% lower OPEX claimed.

On this page

Overview

The Vision Battery news item covers the company's participation in DCWA 2025, Asia's largest data centre event, held 8-9 October 2025 at Marina Bay Sands, Singapore, and its lithium UPS battery solutions. Two products are featured: the classic REVO 2.5 TP200 and the premium REVO 3.0 TPX600.

The REVO 2.5 TP200 uses the company's own 4C high-rate LFP cells, delivers 250 kW per cabinet and provides 10 to 60 minutes of backup. It has four-level safety protection, BMS and module-level fire control, 24/7 intelligent monitoring and a modular, prefabricated design for flexible deployment and scaling.

The REVO 3.0 TPX600 delivers 600 kW per cabinet using 10C high-rate laminated LFP cells. The item states that just 2 cabinets reach 1.2 MW of UPS capacity, reducing footprint by 80% and OPEX by 30%. It has more than 10 layers of safety redundancy, including temperature monitoring, insulation fault detection and CO alarms. The item does not give full mechanical or runtime data.

Key points

  1. Event: DCWA 2025, 8-9 October, Marina Bay Sands, Singapore.
  2. REVO 2.5 TP200: 250 kW per cabinet, 4C LFP cells, 10-60 minutes of backup.
  3. REVO 3.0 TPX600: 600 kW per cabinet, 10C laminated LFP cells.
  4. Two TPX600 cabinets give 1.2 MW of UPS capacity.
  5. Claimed gains: 80% less footprint and 30% lower OPEX.
  6. TPX600 has over 10 safety layers: temperature monitoring, insulation fault detection, CO alarms.
  7. TP200 has four-level protection, BMS and module-level fire control.

Using it in design

  • For high-power, short-duration (10-60 min) LFP backup, divide the UPS power by the per-cabinet kW (250 and 600 kW) to size cabinet count and floor area.
  • Verify the footprint and OPEX claims in your own project calculation against a lead-acid or lower C-rate lithium reference.
  • Map the battery room safety needs (insulation fault detection, CO alarm, fire control) to local fire and lithium battery rules.
  • Request detailed dimension, weight and runtime data from the manufacturer in a project datasheet.

Who should read it

Electrical designers evaluating lithium UPS battery systems for high-density data centres.

Document contents

  1. DCWA 2025 participation
  2. REVO 2.5 TP200
  3. REVO 3.0 TPX600

Publication details

Authors
Vision
Publisher
Vision
Year
Year not stated
Document language
English
Source type
Manufacturer
Access
Free to read
Licence
Copyright retained; citation only: the publisher’s terms apply to the original document
Original licence note

No document-specific redistribution permission was established. Bibliographic reference only.

Citation

Vision REVO 3.0 TPX600 at Data Centre World Asia 2025. Vision. https://www.vision-batt.com/en/news/show/vision-lithium-ups-battery-dcwa-2025.html

All content and rights belong to the respective authors and publishers. SoSo CAD provides only the citation, its own summary and a link to the source, and is not responsible for the sources' content.

Power design in SoSo CAD

Calculate supply paths, equipment loads and UPS failure scenarios as part of the design.

Single-line diagram in the SoSo CAD power and capacity workspace

Keep your reading list current

Once a month: new library sources, changes to Turkish regulations and upcoming data centre events.