REVO 3.0 TPX600 at Data Centre World Asia 2025
Vision
Vision Battery showed the REVO 3.0 TPX600 LFP UPS battery cabinet at DCWA 2025, rated 600 kW per cabinet; two cabinets reach 1.2 MW of UPS capacity with 80% less footprint and 30% lower OPEX claimed.
On this page
Overview
The Vision Battery news item covers the company's participation in DCWA 2025, Asia's largest data centre event, held 8-9 October 2025 at Marina Bay Sands, Singapore, and its lithium UPS battery solutions. Two products are featured: the classic REVO 2.5 TP200 and the premium REVO 3.0 TPX600.
The REVO 2.5 TP200 uses the company's own 4C high-rate LFP cells, delivers 250 kW per cabinet and provides 10 to 60 minutes of backup. It has four-level safety protection, BMS and module-level fire control, 24/7 intelligent monitoring and a modular, prefabricated design for flexible deployment and scaling.
The REVO 3.0 TPX600 delivers 600 kW per cabinet using 10C high-rate laminated LFP cells. The item states that just 2 cabinets reach 1.2 MW of UPS capacity, reducing footprint by 80% and OPEX by 30%. It has more than 10 layers of safety redundancy, including temperature monitoring, insulation fault detection and CO alarms. The item does not give full mechanical or runtime data.
Key points
- Event: DCWA 2025, 8-9 October, Marina Bay Sands, Singapore.
- REVO 2.5 TP200: 250 kW per cabinet, 4C LFP cells, 10-60 minutes of backup.
- REVO 3.0 TPX600: 600 kW per cabinet, 10C laminated LFP cells.
- Two TPX600 cabinets give 1.2 MW of UPS capacity.
- Claimed gains: 80% less footprint and 30% lower OPEX.
- TPX600 has over 10 safety layers: temperature monitoring, insulation fault detection, CO alarms.
- TP200 has four-level protection, BMS and module-level fire control.
Using it in design
- For high-power, short-duration (10-60 min) LFP backup, divide the UPS power by the per-cabinet kW (250 and 600 kW) to size cabinet count and floor area.
- Verify the footprint and OPEX claims in your own project calculation against a lead-acid or lower C-rate lithium reference.
- Map the battery room safety needs (insulation fault detection, CO alarm, fire control) to local fire and lithium battery rules.
- Request detailed dimension, weight and runtime data from the manufacturer in a project datasheet.
Who should read it
Electrical designers evaluating lithium UPS battery systems for high-density data centres.
Document contents
- DCWA 2025 participation
- REVO 2.5 TP200
- REVO 3.0 TPX600
Publication details
- Authors
- Vision
- Publisher
- Vision
- Year
- Year not stated
- Document language
- English
- Source type
- Manufacturer
- Access
- Free to read
- Licence
- Copyright retained; citation only: the publisher’s terms apply to the original document
Original licence note
No document-specific redistribution permission was established. Bibliographic reference only.
Citation
Vision REVO 3.0 TPX600 at Data Centre World Asia 2025. Vision. https://www.vision-batt.com/en/news/show/vision-lithium-ups-battery-dcwa-2025.html
All content and rights belong to the respective authors and publishers. SoSo CAD provides only the citation, its own summary and a link to the source, and is not responsible for the sources' content.