Tescom 2026 catalogue pp.68-69 STS3000-4000
Tescom
Manufacturer pages from Tescom's 2026 catalogue giving the model table and technical values of the 3-phase, 3- and 4-pole STS3000-4000 static transfer switch family from 50 A to 1250 A.
On this page
Overview
The catalogue covers the NEOLINE (1-3 kVA), NEOLINE 100 (6-10 kVA), NEOLINE PRO, NEOLINE RT and NEOLINE PRO RT UPS families, the DS Power and modular MTI series, the STS2000 and STS3000-4000 static transfer switches and communication accessories. The focus here is pages 68 and 69: the STS3000 (3-pole) and STS4000 (4-pole) static transfer switches.
The STS3000-4000 transfers critical loads without interruption to either of two independent AC lines. The system monitors both AC inputs and, if one goes out of tolerance, moves the load to the other. The transfer type is break before make; transfer time is 4 ms or less for synchronous sources and 10 ms or less for non-synchronous sources. Options include automatic, manual and remote transfer, selectable preferred source, maintenance bypass and optional hot-swap. It uses a fuseless SCR design and forced cooling (redundant fans).
The model table separates 11 current steps: 50, 100, 150, 200, 250, 300, 400, 600, 800, 1000 and 1250 A. Each step exists as STS3 (3-pole, meaning 3-phase switching) and STS4 (4-pole, 3-phase plus neutral switching) codes, for example STS3050 and STS4050. Input voltage is 380/400/415 VAC 3-phase + N + earth, the input voltage range is 180-264 VAC phase-to-neutral, frequency 50/60 Hz with a 45-65 Hz range, and efficiency at rated current is up to 99.5%. Overload capacity is continuous up to 100%, 1 minute at 100-150%, 10 seconds at 151-200% and 250 ms above 200%.
Environmental values: operating temperature 0 to 40 °C, humidity below 90%, protection IP20, standards EN 62310-1 and EN 62310-2, noise 52 to 65 dBA by rating. Net weight runs from 139 kg to 610 kg for the STS3000 and from 160 kg to 660 kg for the STS4000; the chassis version of some models is given with lower weights and dimensions in parentheses. Chassis versions have no protection equipment or cabinet covers and are used as building blocks in power distribution systems.
Key points
- STS3000 (3-pole) and STS4000 (4-pole, neutral switching); steps 50, 100, 150, 200, 250, 300, 400, 600, 800, 1000 and 1250 A.
- Break-before-make transfer; 4 ms or less (synchronous sources) and 10 ms or less (non-synchronous).
- Input 380/400/415 VAC 3-phase + N + earth, 180-264 VAC phase-to-neutral, 50/60 Hz, 45-65 Hz.
- Efficiency up to 99.5% at rated current; input voltage THD below 10%.
- Overload: continuous 100%, 100-150% 1 min, 151-200% 10 s, above 200% 250 ms.
- Communication RS232 standard, SNMP and RS485 optional; 4 programmable alarm relays.
- Operating 0 to 40 °C, IP20, EN 62310-1 and EN 62310-2, noise 52-65 dBA.
- Net weight 139-610 kg for the STS3000 and 160-660 kg for the STS4000.
- Chassis versions have no protection equipment or cabinet covers.
Using it in design
- In static transfer switch selection record the current step (50-1250 A) and pole count (3 or 4) together; the 4-pole choice is for neutral isolation.
- Compare the 4 ms (synchronous) or 10 ms (non-synchronous) transfer time with the hold-up time of the IT load.
- Check whether the two sources are synchronous (for example different transformers or a generator); non-synchronous transfer takes longer.
- For floor loading and layout use the STS3000 and STS4000 weights by model (for example 610 and 660 kg for 1250 A).
- Treat the STS itself as a single point of failure in the redundancy analysis and include the maintenance bypass in the design.
- Remember that the chassis type has no protection or cabinet; specify protective devices separately in the panel design.
Who should read it
Electrical engineers designing dual-fed (A/B) critical load distribution and teams writing STS specifications.
Document contents
- Catalogue contents: NEOLINE, DS Power, MTI modular UPS families
- STS2000 static transfer switch
- STS3000-4000 static transfer switch: general features
- STS3000-4000 technical specifications
- Communication and software accessories
Publication details
- Authors
- Tescom
- Publisher
- Tescom
- Year
- 2026
- Document language
- Turkish
- Source type
- Manufacturer
- Access
- Free to read
- Licence
- Copyright retained; citation only: the publisher’s terms apply to the original document