Aunilec HELIOS-TH 10-100 kVA Three-Phase Modular UPS

Original title Aunilec HELIOS-TH brochure, technical table p.4 (image verified)

Aunilec

Aunilec HELIOS-TH is a 10-100 kVA three-level double-conversion modular UPS with 10 or 20 kVA modules, N+1 redundancy, VFI-SS-111 and 95.5% efficiency in normal mode and 99% in ECO mode.

On this page

Overview

The brochure presents the HELIOS-TH as a modular double-conversion UPS with three-phase input and output and three-level converter technology. Four cabinet configurations are given: 10-30 kVA (10 kVA modules, 3 slots), 10-50 kVA (10 kVA, 5 slots), 20-60 kVA (20 kVA, 3 slots) and 20-100 kVA (20 kVA, 5 slots). For N+1 redundancy one extra module is needed above the desired output power. Cabinets measure 1200 x 600 x 850 mm and 1400 x 600 x 850 mm.

Features: input power factor 1, VFI-SS-111 class, ECO mode switching, hot-swappable power modules, front-replaceable fans and filters, a redundant parallel control unit and N+X parallel operation of up to 4 systems. The Power Walk In function starts the rectifier gradually and avoids inrush peaks on the supply; Inter Power Walk In starts several UPS units in sequence. An intelligent standby mode deactivates modules at low load to raise efficiency.

Technical data: input 380/400/415 Vac, 138-485 Vac, 40-70 Hz, THDi below 3% (100% non-linear load), output regulation ±1%, efficiency 95.5% in normal mode and 99% in ECO mode. Battery ±180 to ±300 Vdc (30-50 blocks), charge current 18 A per module, recharge from 5 hours. Overload goes to bypass after 60 min at 105-110%, 10 min at 110-125% and 1 min at 125-150%; above 150% it shuts down at once. Operation is 0-40 °C (recommended +15 to +25 °C), noise below 58-61 dB, warranty 5 or 10 years depending on battery type.

Key points

  1. Power ranges: 10-30, 10-50, 20-60 and 20-100 kVA/kW; 10 or 20 kVA modules.
  2. VFI-SS-111; output PF 1; 95.5% efficiency in normal mode, 99% in ECO mode.
  3. N+1 needs one extra module above the output power; up to 4 systems N+X in parallel.
  4. Input 380/400/415 Vac, 138-485 Vac, 40-70 Hz; THDi <3%.
  5. Battery ±180 to ±300 Vdc (30-50 blocks), 18 A charging per module.
  6. Overload: 105-110% 60 min, 110-125% 10 min, 125-150% 1 min then bypass; >150% shutdown.
  7. Cabinet 1200 x 600 x 850 mm or 1400 x 600 x 850 mm; about 150 and 180 kg without batteries.
  8. Module weight about 21 kg; 0-40 °C, IP20, EN 62040-1, -2, -3.

Using it in design

  • Choose the module count so one spare module remains for N+1, and record the 100 kVA cabinet ceiling in the growth plan.
  • Set Power Walk In together with generator load acceptance on generator-fed systems.
  • Calculate battery block count and charge current (18 A per module) against autonomy and recharge targets.
  • When selecting on ECO efficiency, account for the changed protection class in that mode.
  • Use the 150-180 kg cabinet weight and the 1200/1400 mm height for floor loading and layout.

Who should read it

Electrical designers selecting scalable three-phase UPS units for data-centre and industrial sites.

Document contents

  1. Modular UPS and efficiency
  2. Service concept
  3. Redundant power modules and Power Walk In
  4. Connections
  5. Redundant and scalable cabinets
  6. Features and technical data

Publication details

Authors
Aunilec
Publisher
Aunilec
Year
Year not stated
Document language
French
Source type
Manufacturer
Access
Free to read
Licence
Copyright retained; citation only: the publisher’s terms apply to the original document
Original licence note

No document-specific redistribution permission was established. Bibliographic reference only.

Citation

Aunilec Aunilec HELIOS-TH brochure, technical table p.4 (image verified). Aunilec. https://onduleurs-aunilec.com/gb/index.php?controller=attachment&id_attachment=200

All content and rights belong to the respective authors and publishers. SoSo CAD provides only the citation, its own summary and a link to the source, and is not responsible for the sources' content.

Power design in SoSo CAD

Calculate supply paths, equipment loads and UPS failure scenarios as part of the design.

Single-line diagram in the SoSo CAD power and capacity workspace

Keep your reading list current

Once a month: new library sources, changes to Turkish regulations and upcoming data centre events.