Static Power iSTS R: rail-mounted 16 A single-phase static transfer switch

Original title Static Power iSTS Model R datasheet, p.2

Static Power

The Static Power iSTS R is a DIN-rail-mounted 16 A single-phase static transfer switch: synchronous break up to a quarter cycle, 12.5 ms asynchronous, MTBF over 500,000 hours, 0.7 kg.

On this page

Overview

The brochure presents the rail-mounted iSTS R, designed for PLCs, CNCs, robotics, BMS, workshop IT, engineering and office workstations and warehouses. The unit avoids supply disruptions to critical manufacturing and IT equipment by changing transparently to a secondary source if the preferred one fails. It is single-phase, 2-pole, 16 A maximum.

Two uses are described: in buildings it is installed in a floor or office switchboard to replace individual UPSs that are not always reliable and are hard to maintain; in industry, typically an Industry 4.0 environment, it guarantees continuous supply to all PLCs, CNCs and controls in the workshop.

Technical values: voltage 115 V or 230 V +/-10%, frequency 50/60 Hz +/-10% with auto detection, and break-before-make zero-current transfer by thyristors/SCR. Synchronous break time is up to a quarter cycle and asynchronous break time is 12.5 ms (dynamic break time); detection is digital (<1 ms). Device ratings are 56 ARMS, 1200 V and 300 A for 1 cycle. Overload is 32 A for 30 s, 63 A for 1 s, 100 A for 2 cycles and 300 A for 1 cycle; the fault-current setting is 250% peak.

Physical: 215x60x90 mm (L x D x H), weight 0.7 kg, operating temperature 0-35 °C, IP30, cooling by redundant fans, humidity 5-95% non-condensing. Input and output are terminals up to 4 mm². Protection is an external DIN-rail 10x38 mm 16/20 A fuse isolator; there is no source isolation. There is no practical power factor limit, crest factor is 3:1 and permitted source distortion is at most 10% THDV.

Key points

  1. DIN-rail mounted, 1-phase 2-pole, 16 A maximum; 115 V or 230 V +/-10%; 50/60 Hz.
  2. Synchronous break up to a quarter cycle; asynchronous 12.5 ms; detection <1 ms.
  3. MTBF over 500,000 hours; built-in transient voltage protection; RCD site compatible.
  4. Overload: 32 A/30 s, 63 A/1 s, 100 A/2 cycles, 300 A/1 cycle; fault current 250% peak.
  5. Size 215x60x90 mm, weight 0.7 kg; 0-35 °C; IP30; redundant fan cooling.
  6. Protection: external 10x38 mm 16/20 A fuse isolator; no source isolation.
  7. No practical power factor limit; crest factor 3:1; source THDV at most 10%.
  8. Applications: PLC, CNC, robotics, BMS, workshop IT, office workstations.

Using it in design

  • When considering the iSTS R in a floor board instead of individual UPSs, verify the load's tolerance to the 12.5 ms asynchronous transfer time.
  • Compare the 16 A limit with load current and the 32 A/30 s and 63 A/1 s overload values; if the load has inrush, check the 100 A/2-cycle limit.
  • Add the external 10x38 mm fuse isolator to the board diagram and selectivity calculation; the unit has no source isolation.
  • With an operating temperature of 0-35 °C, plan board internal temperature and redundant-fan maintenance.
  • Show on the diagram that the preferred and secondary sources come from different upstream feeds.

Who should read it

Electrical designers and panel builders protecting critical single-phase loads with dual feeds in industrial and commercial buildings.

Document contents

  1. Features
  2. Applications for building and for industry
  3. Technical specification
  4. Dimensions, environment and protection

Publication details

Authors
Static Power
Publisher
Static Power
Year
Year not stated
Document language
English
Source type
Manufacturer
Access
Free to read
Licence
Copyright retained; citation only: the publisher’s terms apply to the original document
Original licence note

No document-specific redistribution permission was established. Bibliographic reference only.

Citation

Static Power Static Power iSTS Model R datasheet, p.2. Static Power. https://staticpower.com.au/wp-content/uploads/2019/03/iSTS-Model-R.pdf

All content and rights belong to the respective authors and publishers. SoSo CAD provides only the citation, its own summary and a link to the source, and is not responsible for the sources' content.

Power design in SoSo CAD

Calculate supply paths, equipment loads and UPS failure scenarios as part of the design.

Single-line diagram in the SoSo CAD power and capacity workspace

Keep your reading list current

Once a month: new library sources, changes to Turkish regulations and upcoming data centre events.