Parus Electro: AC Uninterruptible Power Supplies
Original title Парус электро: Источники бесперебойного питания переменного тока
Parus Electro
The Russian maker Parus Electro's UPS catalogue presentation: double-conversion series from 1 kVA single-phase to 1000 kVA modular three-phase, with ECO mode efficiency up to 98.5% and 50 kW 3U power modules.
On this page
Overview
The presentation introduces the Parus Electro UPS family for telecom, IT and data centres, industry, oil and gas, energy, medicine and infrastructure systems. All products use double-conversion (online) technology: mains voltage is converted to an internal DC bus, the inverter creates high-quality AC output, and because batteries sit on the DC bus there is no switchover time on battery operation. In a fault the unit does not shut down but moves to bypass and feeds the load from the mains.
The catalogue proceeds series by series by power class: SIPB 1-3 kVA single-phase floor-standing (power factor 1.0, input 110-300 V, input power factor 0.99 or above, internal 12 V/9 Ah batteries, ECO mode at 95% or above), SIPB RT rack-mount 1-3 kVA and 6-10 kVA, SIPB 10-20 kVA three-phase, SIP380A 10-40 kVA and 60-200 kVA compact, SIP380B 10-800 kVA and modular SIP380A MD 6-200 kVA, 20-200 kVA and 150-1000 kVA. Model tables for each series give input, output, efficiency, battery and environment values.
For example, the compact SIP380A 10-40 kVA has normal-mode efficiency of 93.5-94.5% and 98.5% in ECO mode; two or three groups of 12 V/9 Ah internal batteries can be fitted, with external battery cabinets extending autonomy. The 150-1000 kVA modular series uses 50 kW, 3U hot-swappable power modules and offers N+x power-module redundancy, parallel operation of up to 6 cabinets, a DC bus adjustable for 30-50 batteries, operation with lithium battery cabinets, and Modbus RTU, SNMP v2/3 and dry-contact integration.
This is a Russian-language manufacturer presentation that highlights product advantages and contains no independent test data. Table values are the manufacturer's declaration for nominal conditions.
Key points
- All series are double-conversion (online) UPS; switchover time on battery is zero and the unit goes to bypass on a fault.
- SIPB 1-3 kVA: power factor 1.0, input voltage 110-300 V, input THDi under 5%, input power factor 0.99 or above, efficiency 90-92% or above, ECO mode 95% or above, internal 12 V/9 Ah batteries, 4 hours to 90% charge.
- SIPB 1-3 kVA overload: on mains 1 minute at 105-125%, 30 seconds at 125-130%, bypass above 130%; on battery 10 seconds at 125-130%.
- SIP380A 10-40 kVA compact: normal-mode efficiency 93.5-94.5%, ECO mode 98.5%; internal battery space for two or three groups of 12 V/9 Ah.
- Range: 1-3 kVA and 6-10 kVA single-phase, 10-20 kVA three-phase, 10-800 kVA (SIP380B) and modular 6-1000 kVA (SIP380A MD).
- The modular 150-1000 kVA series uses 50 kW 3U hot-swap modules, a redundant control module and a dedicated bypass module; 3 x 50 kVA makes 150 kVA and 8 x 50 kVA makes 400 kVA.
- The modular series offers N+x redundancy and parallel operation of up to 6 UPS cabinets; the DC bus is adjustable for 30-50 batteries and can work with lithium battery cabinets.
- Monitoring is via Modbus RTU, SNMP v2/3 and dry contacts; ECO mode efficiency of the modular series is 98% or above.
Using it in design
- Choose the series by power class and mounting form (floor, rack, modular cabinet) together with load growth; in the 150-1000 kVA range N+x redundancy can be built in 50 kW module steps.
- Ask for efficiency by load fraction rather than a single point; weigh the protection loss of ECO mode against load sensitivity (ECO efficiency 98% and above against normal mode 93.5-94.5%).
- In battery cabinet design check the UPS DC bus range (30-50 batteries) and lithium battery compatibility.
- Assess input power factor, THDi and the wide input voltage range (for example 110-300 V) against generator and weak-grid conditions.
- State the Modbus RTU, SNMP and dry-contact interfaces for monitoring integration, and have the presentation values confirmed against the detailed data sheet.
Who should read it
Electrical designers and procurement specialists selecting UPS in the Russian and CIS market, and engineers comparing the maker's series.
Document contents
- UPS introduction and double-conversion technology
- SIPB 1-3 kVA single-phase series
- SIPB RT series 1-3 kVA and 6-10 kVA
- SIPB 10-20 kVA three-phase series
- SIP380A and SIP380B series 10-800 kVA
- SIP380A MD modular series 6-1000 kVA
Publication details
- Authors
- Parus Electro
- Publisher
- Parus Electro
- Year
- Year not stated
- Document language
- Russian
- Source type
- Manufacturer
- Access
- Free to read
- Licence
- Copyright retained; citation only: the publisher’s terms apply to the original document
Original licence note
No document-specific redistribution permission was established. Bibliographic reference only.
Citation
Parus Electro Парус электро: Источники бесперебойного питания переменного тока. Parus Electro. https://parus-electro.ru/presentations/02_ups_ac.pdf
All content and rights belong to the respective authors and publishers. SoSo CAD provides only the citation, its own summary and a link to the source, and is not responsible for the sources' content.