EPI Group Company Profile 2025

EPI UPS

A manufacturer company profile presenting the EPI UPS group's product families, power ranges, production and office structure, and reference customers.

On this page

Overview

The document describes EPI as a global UPS manufacturer with factories in Italy, Turkey and China, more than 38 years of history and offices in 20 countries. Besides UPS, it states that the group also makes static transfer switches (STS), automatic voltage regulators (AVR), batteries, automatic transfer switches (ATS), phase-sequence correction devices (PCD), micro data centres and connectivity software. The product range is given as up to 1,000 kVA, with parallel configurations up to 8 MVA, and a new assembly plant in Istanbul is said to complement the Shenzhen facility to strengthen the supply chain.

The product section lists the power range of each family: MHP/MHPR and MTP single-phase 1-10 kVA; TCA tower/rack 10-60 kVA; XR+ high-frequency 10-800 kVA; XRT transformer-based industrial 10-600 kVA; Xtreme X 10-800 kVA (unity power factor, up to 98.5% efficiency in eco mode, N+1 and N+X parallel redundancy); TG+ low-frequency transformer-based 10-100 kVA (3/1) and 10-1000 kVA (3/3); RMD modular 10-2000 kVA. The single-phase n-STS is presented in the 16-120 A range with transfer faster than a quarter cycle.

Other products include the 10-2000 kVA servo or static AVR 33 series, the 10-2000 kVA PCD and the 3-10 kVA Pro-Smart micro integrated data centre, which combines rack, power distribution, cooling, monitoring and fire suppression in 0.72-20 square metres and is stated to achieve PUE below 1.5. The profile also contains management biographies, vision and mission texts and a reference list of public and private customers in Bangladesh, Hong Kong and other countries.

The contact section gives many company addresses in the same group document, including Italy (EPI UPS (Italy) srls, Forli) and Turkey (EPI UPS Innovasis Enerji Ltd, Istanbul). The document is promotional and contains no technical performance data; the power ranges of the product families are the manufacturer's own statements and do not amount to a factory audit or independent performance evidence.

Key points

  1. Factories in Italy, Turkey and China; 38+ years, offices in 20 countries; range up to 1,000 kVA and 8 MVA in parallel.
  2. Single-phase families: MHP/MHPR and MTP, 1-10 kVA; MTP charging capacity can be customised up to 12 A.
  3. Three-phase families: TCA 10-60 kVA, XR+ 10-800 kVA, XRT 10-600 kVA, Xtreme X 10-800 kVA, TG+ 10-1000 kVA (3/3), RMD modular 10-2000 kVA.
  4. The Xtreme X family states unity power factor (kW=kVA), input power factor above 0.99, up to 98.5% efficiency in eco mode and N+1, N+X parallel redundancy.
  5. n-STS single-phase STS 16-120 A; thyristor switching with transfer faster than a quarter cycle; manual bypass, hot swap, programmable dry contacts.
  6. AVR 33 series (servo or static) and PCD devices span 10-2000 kVA.
  7. The Pro-Smart micro integrated data centre is 3-10 kVA in 0.72-20 square metres with PUE stated below 1.5.
  8. The document gives company addresses in Italy (Forli) and Turkey (Istanbul) within one group; the contact section lists many country offices.

Using it in design

  • Record EPI family names and power ranges in the catalogue as manufacturer statements, and refer to product datasheets for model-specific data.
  • When comparing the 10-2000 kVA modular (RMD) and 10-800 kVA XR+ families in the same power class, assess the redundancy structure (N+X, N+1) separately.
  • Use the brand and company relationships (EPI UPS Italy srls, EPI UPS Innovasis Enerji) in supplier assessment as address information taken from the document, and request separate documents as evidence of production site.
  • When adding micro data centre and STS products to data centre templates, use only the ranges given in the document (16-120 A, 3-10 kVA).

Who should read it

Procurement and electrical engineers assessing UPS suppliers, and teams preparing a product catalogue.

Document contents

  1. About us
  2. Our solutions
  3. Vision and mission
  4. Meet our management
  5. Products highlight
  6. Our major clients
  7. Contact and offices

Publication details

Authors
EPI UPS
Publisher
EPI UPS
Year
2025
Document language
English
Source type
Manufacturer
Access
Free to read
Licence
Copyright retained; citation only: the publisher’s terms apply to the original document
Original licence note

No document-specific redistribution permission was established. Bibliographic reference only.

Citation

EPI UPS (2025). EPI Group Company Profile 2025. EPI UPS. https://epi-ups.com/wp-content/uploads/2025/08/EPI-Group-Company-Profile.pdf

All content and rights belong to the respective authors and publishers. SoSo CAD provides only the citation, its own summary and a link to the source, and is not responsible for the sources' content.

Power design in SoSo CAD

Calculate supply paths, equipment loads and UPS failure scenarios as part of the design.

Single-line diagram in the SoSo CAD power and capacity workspace

Keep your reading list current

Once a month: new library sources, changes to Turkish regulations and upcoming data centre events.