OUXIPER GSTS Series Isolated Static Transfer Switch (STS)

Original title OUXIPER GSTS Static Transfer Switch technical overview

OUXIPER

OUXIPER GSTS is a family of isolated static transfer switches (STS) for three-phase systems from 25 to 800 A, with a typical switching time of 4 ms or less.

On this page

Overview

GSTS is OUXIPER's static transfer switch product family. The family page covers a three-phase continuous current range from 25 A to 800 A. This is a continuous range, not a discrete model list; selection is made within it according to load current.

Typical switching time is 4 ms or less. For data centre applications that need uninterrupted load transfer between two independent power sources, this is the main performance figure of an STS, to be compared with the ride-through tolerance between UPS output and sensitive loads.

OUXIPER also supplies automatic transfer switches (ATS), power distribution units (PDU) and precision cooling; the GSTS page sits among its critical power assurance solutions for data centres, rail transit and energy.

Key points

  1. Product: GSTS isolated static transfer switch (STS), three-phase.
  2. Continuous current range 25-800 A.
  3. Typical switching time 4 ms or less.
  4. The range is continuous, not a discrete model list.
  5. The maker also supplies ATS, PDU and precision cooling products.

Using it in design

  • Select within the 25-800 A range by load current and confirm the discrete current rating from the product datasheet.
  • Compare the 4 ms switching time with the tolerance curve of server power supplies.
  • Position the STS between two independent UPS lines so that it does not become a single point of failure.

Who should read it

Electrical designers selecting an STS for dual-fed critical loads.

Publication details

Authors
OUXIPER
Publisher
OUXIPER
Year
Year not stated
Document language
Chinese
Source type
Manufacturer
Access
Free to read
Licence
Copyright retained; citation only: the publisher’s terms apply to the original document
Original licence note

No document-specific redistribution permission was established. Bibliographic reference only.

Citation

OUXIPER OUXIPER GSTS Static Transfer Switch technical overview. OUXIPER. https://www.ouxiper.cn/products/gsts

All content and rights belong to the respective authors and publishers. SoSo CAD provides only the citation, its own summary and a link to the source, and is not responsible for the sources' content.

Power design in SoSo CAD

Calculate supply paths, equipment loads and UPS failure scenarios as part of the design.

Single-line diagram in the SoSo CAD power and capacity workspace

Keep your reading list current

Once a month: new library sources, changes to Turkish regulations and upcoming data centre events.