CyberPower PDU44002 official specifications

CyberPower

CyberPower PDU44002 switched ATS PDU: 20 A rated current, maximum 20 A input and a separately stated 16 A derated operating input; a discrete current rating for source-transfer selection.

On this page

Overview

CyberPower's product page lists the PDU44002 as a switched PDU with automatic source transfer (ATS). The page provides discrete current ratings and product-specific configuration limits for selecting automatic source transfer. These ratings do not prove local certification, stock or site suitability.

The PDU44002 has a rated current of 20 A. The maximum input is 20 A, and a separate 16 A derated operating input is stated. The two values should be read separately: 20 A is the device limit and 16 A is the input current under the derated operating condition.

Key points

  1. Model PDU44002; rated current 20 A.
  2. Maximum input current 20 A.
  3. Separately stated derated operating input 16 A.
  4. Ratings do not prove local certification or stock.

Using it in design

  • Check the rack load against the 16 A derated operating input; 20 A is the device limit.
  • Size the feeder protection and cable of each of the two sources to the 20 A input limit.
  • Place the ATS PDU in the redundancy scheme as a way to give single-corded IT equipment a second supply.
  • Verify local certification and supply status separately.

Who should read it

Electrical and rack infrastructure engineers planning backup source transfer for single-corded IT equipment.

Publication details

Authors
CyberPower
Publisher
CyberPower
Year
Year not stated
Document language
English
Source type
Manufacturer
Access
Free to read
Licence
Copyright retained; citation only: the publisher’s terms apply to the original document
Original licence note

No document-specific redistribution permission was established. Bibliographic reference only.

Citation

CyberPower CyberPower PDU44002 official specifications. CyberPower. https://cyberpowersystems.com/product/pdu/switched-ats/pdu44002

All content and rights belong to the respective authors and publishers. SoSo CAD provides only the citation, its own summary and a link to the source, and is not responsible for the sources' content.

Power design in SoSo CAD

Calculate supply paths, equipment loads and UPS failure scenarios as part of the design.

Single-line diagram in the SoSo CAD power and capacity workspace

Keep your reading list current

Once a month: new library sources, changes to Turkish regulations and upcoming data centre events.