NASN POWER Single Phase Transfer Switch Available Models (16-125 A, 2026-01-16)

Original title NASN POWER Single Phase Transfer Switch available models, 2026-01-16

NASN POWER

NASN POWER's single-phase static transfer switch (STS) comes in 16, 25, 32, 40, 45, 63, 80, 100 and 125 A models; transfer time is under 4 ms in the thyristor version and 5 to 8 ms in the relay version.

On this page

Overview

The NASN POWER single-phase static transfer switch offers true redundancy and high reliability for automatic power supply switching. Available models are 16, 25, 32, 40, 45, 63, 80, 100 and 125 A. There are two versions: a silicon-controlled (thyristor) version with transfer time under 4 ms and a relay version with 5 to 8 ms. The page is dated 16 January 2026.

In normal operation the load stays on the main source; when the main source fails, it switches automatically to the backup. Switching uses break-before-make logic with high-speed thyristor modules and gives uninterrupted transfer between different input sources. The STS is designed to give dual-circuit supply to single-power-input equipment.

In the architecture the page describes, feed A (for example UPS-A) supplies the equipment and feed B (UPS-B) is hot backup; if A fails, the STS moves to B. Listed applications include power plants and dispatch centres, air traffic control and satellite communication, nuclear-industry safety and process control, financial computer centres, e-commerce data processing centres and large and mid-size industrial and mining enterprises. The page gives no voltage, overload or dimension table.

Key points

  1. Nine current ratings: 16, 25, 32, 40, 45, 63, 80, 100, 125 A; single phase.
  2. Transfer time under 4 ms in the thyristor version; 5 to 8 ms in the relay version.
  3. Break before make: break first, then connect; high-speed thyristor module.
  4. On main source failure, the load transfers automatically to the backup.
  5. UPS-A / UPS-B structure: A feeds, B is hot backup.
  6. Designed to give dual-circuit supply to single-power-input IT equipment.
  7. Backup source can be a UPS, mains or generator.
  8. Applications: power plant, air traffic control, financial computer centre, e-commerce data centre.

Using it in design

  • To feed single-input equipment from two independent UPS lines, place the STS near the rack on the load side.
  • Compare transfer time with the load's hold-up time: under 4 ms thyristor, 5 to 8 ms relay.
  • Select the switch current against the load's continuous current from the nine ratings between 16 and 125 A.
  • Assess source synchronisation and the STS as a single point of failure in the redundancy analysis.

Who should read it

Electrical designers and buyers needing source redundancy for single-corded equipment.

Document contents

  1. Single phase transfer switch models
  2. Operating principle
  3. Redundant UPS system
  4. Applications

Publication details

Authors
NASN POWER
Publisher
NASN POWER
Year
Year not stated
Document language
English
Source type
Manufacturer
Access
Free to read
Licence
Copyright retained; citation only: the publisher’s terms apply to the original document
Original licence note

No document-specific redistribution permission was established. Bibliographic reference only.

Citation

NASN POWER NASN POWER Single Phase Transfer Switch available models, 2026-01-16. NASN POWER. https://nasncharger.com/Single-Phase-Transfer-Switch-16A-25A-32A-40A-45A-63A-80A-100A-125A-id48781855.html

All content and rights belong to the respective authors and publishers. SoSo CAD provides only the citation, its own summary and a link to the source, and is not responsible for the sources' content.

Power design in SoSo CAD

Calculate supply paths, equipment loads and UPS failure scenarios as part of the design.

Single-line diagram in the SoSo CAD power and capacity workspace

Keep your reading list current

Once a month: new library sources, changes to Turkish regulations and upcoming data centre events.