Power Inspired VFI-T Series 1-3 kVA Online UPS Specification Sheet

Original title Power Inspired VFI-T datasheet REV2, pp.2–3

Power Inspired

Power Inspired VFI-T is a 1, 2 and 3 kVA high-frequency double-conversion tower UPS with 0.9 output power factor, 0.99 input power factor, 94% efficiency in ECO mode and up to 4 matching battery modules.

On this page

Overview

The sheet describes the VFI-T models 1000 VA / 900 W, 2000 VA / 1800 W and 3000 VA / 2700 W. The series is a high-frequency double-conversion UPS family with 0.9 output power factor, extended run capability, EPO, load shed and an intelligent port. A three-stage charger extends battery life and optimises recharge time; cold start, standard RS232 and USB, and optional SNMP and relay cards are included.

Input is nominal 220/230/240 V AC with a 200-290 V AC window at full load, 50/60 Hz ±10%, input power factor at least 0.99 and maximum input current of 4.9 / 9.5 / 14.2 A. Output is 200/208/220/230/240 V AC ±1%, crest factor 3:1, THDv below 3% on linear load. Efficiency is above 89% and above 94% in ECO mode. The battery is 36 V (12 V 9 Ah x3) and 72 V (x6); typical recharge is 5 hours to 90% at 1 A.

Transfer from mains to battery is zero and to bypass under 4 ms; overload capacity is 150% for 30 s, then 300 ms. Operating environment is 0-40 °C, 0-95% humidity, altitude below 1500 m, noise below 55 dB. Dimensions are 144x400x215 mm (13 kg) and 191x468x337 mm (24.6 and 25.5 kg). External battery packs are BP1000T (36 V 18 Ah, ~29 kg) and BP3000T (72 V 18 Ah, ~40 kg), VRSLA with a 250 V 30 A DC fuse. Standards are EN 62040-1 / EN 60950-1 and IEC 61000-4-5/-6/-8.

Key points

  1. Three models: 1000 VA / 900 W, 2000 VA / 1800 W, 3000 VA / 2700 W.
  2. Input power factor at least 0.99; operating range 200-290 V AC (full load); frequency 50/60 Hz ±10%.
  3. Output 200-240 V ±1%; crest factor 3:1; THDv below 3% on linear load.
  4. Efficiency above 89%; above 94% in ECO mode.
  5. Battery 36 V (12 V 9 Ah x3) or 72 V (x6); recharge to 90% in 5 hours; charge current 1.0 A.
  6. Transfer: zero mains to battery, under 4 ms to bypass; overload 150% for 30 s.
  7. Up to 4 external battery modules; BP1000T 36 V 18 Ah ~29 kg, BP3000T 72 V 18 Ah ~40 kg.
  8. Environment 0-40 °C, 0-95% humidity, altitude below 1500 m, noise below 55 dB.

Using it in design

  • In small server and network cabinets, compare the 25.5 kg weight and 191x468x337 mm size of the 3 kVA model with the layout.
  • Calculate the number of external battery packs (maximum 4) for the autonomy target and add each pack's ~29-40 kg to the floor loading plan.
  • Allow for longer recharge as runtime extends, given the 1 A charge current.
  • Specify the SNMP or relay card if monitoring is required.
  • If ECO mode is used, compare the sub-4 ms bypass transfer with load tolerance.

Who should read it

Designers selecting tower UPS for edge, network and small IT rooms.

Document contents

  1. Features
  2. Specifications
  3. Physical
  4. Standards
  5. External Battery Packs

Publication details

Authors
Power Inspired
Publisher
Power Inspired
Year
Year not stated
Document language
English
Source type
Manufacturer
Access
Free to read
Licence
Copyright retained; citation only: the publisher’s terms apply to the original document
Original licence note

No document-specific redistribution permission was established. Bibliographic reference only.

Citation

Power Inspired Power Inspired VFI-T datasheet REV2, pp.2–3. Power Inspired. https://www.powerinspired.com/brochures/SS-VFI-T.pdf

All content and rights belong to the respective authors and publishers. SoSo CAD provides only the citation, its own summary and a link to the source, and is not responsible for the sources' content.

Power design in SoSo CAD

Calculate supply paths, equipment loads and UPS failure scenarios as part of the design.

Single-line diagram in the SoSo CAD power and capacity workspace

Keep your reading list current

Once a month: new library sources, changes to Turkish regulations and upcoming data centre events.