KVA Oxxigen 50A automatic generator transfer panel: technical table
Original title KVA Oxxigen 50A complete generator automatic transfer panel, technical table
KVA
The KVA Oxxigen 50A is a complete generator control and automatic transfer panel for loads up to 50 A (AC1), used with generators up to 19 kVA at 220 Vac or 33 kVA at 380 Vac.
On this page
Overview
The Oxxigen 50A is a complete control and automatic transfer panel (QCTA) that KVA designed for small generator sets. The manufacturer's product page states that the model serves loads up to 50 A in utilisation category AC1. The page has Overview, Specifications and Downloads tabs; the technical table gives electrical data, transfer arrangement, components, protections and physical data under separate headings.
Electrically, the rated load current is 50 A (AC1) and the generator it can accompany is rated up to 19 kVA at 220 Vac and 33 kVA at 380 Vac. The alternator voltage range is 180-380 Vac phase to phase, frequency 50/60 Hz and the current transformer is 50/5 A. The control circuit is supplied at 8-32 Vdc; battery voltage is 12 or 24 Vdc, with 12 Vdc as the factory setting.
Transfer is open-transition (a break occurs) through two contactors that are interlocked both electrically and mechanically. The component list names a K30 XL controller, a K21 PRO battery charger, one protective breaker, one current transformer and eight controller fuses. Mains protections are under/over-voltage (27/59); generator protections are under/over-voltage, under/over-frequency (81) and time-delayed overcurrent (51). Engine protections cover temperature, oil pressure, water level, overspeed, start failure and overload.
The panel measures 400 × 400 × 205 mm and weighs 9 kg; the manufacturer gives a 15-month warranty (legal plus 12 additional months). The download section holds the operating manual and the electrical connection drawing. The page covers one model only; values for the other current ratings of the family are on their own pages.
Key points
- Maximum load current 50 A in utilisation category AC1.
- Accompanying generator rating: up to 19 kVA at 220 Vac and 33 kVA at 380 Vac.
- Alternator voltage 180-380 Vac (phase to phase), frequency 50/60 Hz, current transformer 50/5 A.
- Control supply 8-32 Vdc; battery 12 or 24 Vdc (factory setting 12 Vdc).
- Open-transition transfer with two contactors, electrical and mechanical interlock.
- Components: K30 XL controller, K21 PRO charger, one protective breaker, one CT, eight controller fuses.
- Mains protection 27/59; generator protection 27/59, 81 and 51; engine protection for temperature, oil pressure, water level, overspeed, start failure and overload.
- Size 400 × 400 × 205 mm, weight 9 kg; 15-month warranty.
Using it in design
- Compare the generator rating with the limit at the chosen voltage (19 kVA at 220 Vac, 33 kVA at 380 Vac) and confirm the load current stays within 50 A AC1.
- Account for the load break of open-transition transfer; place loads that cannot tolerate it behind a UPS.
- Check that the CT ratio and the alternator voltage range match the generator output.
- Carry the mains and generator protection functions into the protection coordination study.
- Verify panel size and weight against the wall or plant-room mounting location.
Who should read it
Electrical designers and site engineers selecting automatic transfer panels for small generator sets.
Document contents
- Overview
- Specifications: Electrical
- Specifications: Transfer and Components
- Specifications: Protections
- Specifications: General (size, weight, warranty)
- Downloads
Publication details
- Authors
- KVA
- Publisher
- KVA
- Year
- Year not stated
- Document language
- English
- Source type
- Manufacturer
- Access
- Free to read
- Licence
- Copyright retained; citation only: the publisher’s terms apply to the original document
Original licence note
No document-specific redistribution permission was established. Bibliographic reference only.
Citation
KVA KVA Oxxigen 50A complete generator automatic transfer panel, technical table. KVA. https://kva.com.br/produto/oxxigen-50a/
All content and rights belong to the respective authors and publishers. SoSo CAD provides only the citation, its own summary and a link to the source, and is not responsible for the sources' content.