Technical guideFree to readYear not stated

FEEO 2P Chave de Transferência Automática ATS, technical table

FEEO

A Portuguese-language product page from Chinese manufacturer Yueqing Feeo Electric describing its 2-pole CB-class automatic transfer switch (ATS) in eight current ratings: 10, 16, 20, 25, 32, 40, 50 and 63 A, with a short-circuit breaking capacity of 3 kA and a transfer time of at most 3 seconds.

On this page

Overview

The page presents the 2-pole automatic transfer switch of Yueqing Feeo Electric Co., Ltd., founded in 2000 and making photovoltaic system products in the Wenzhou area. The company works from about 2000 m² with around 70 staff; its range covers DC breakers, surge protective devices, fuses, combiner boxes and AC series products. Within that range the ATS is a modular device that switches automatically between two sources, aimed at solar and small distribution applications.

The technical table gives one product family in eight rated working currents: 10, 16, 20, 25, 32, 40, 50 and 63 A. Rated working voltage is AC 400 V, control voltage AC 230 V, rated insulation voltage AC 500 V and frequency 50/60 Hz. Rated short-circuit breaking and making capacity are both stated as 3 kA. Transfer time is less than or equal to 3 seconds. The ATS class is CB, meaning the device is breaker-based and able to interrupt short-circuit current; the standard cited is IEC 60947-1.

The product description lists four features: a compact structure with a protective shield; protection functions against short circuit, overload, open phase and loss of voltage; remote double disconnection with a DC 12-24 V interface for the fire protection supply (EPS); and noiseless operation with simple installation. CB class means the device provides overcurrent protection without a separate upstream element; the 3 kA breaking capacity, however, limits its use to final circuits with low prospective fault current.

The page gives no mechanical or electrical life, utilisation category, dimensions, weight or environmental conditions. With a transfer time of up to 3 seconds the device does not provide continuity at a point feeding IT load directly; it is used on circuits with a UPS downstream or on auxiliary loads that tolerate a short interruption. In a data-centre context its typical place is lighting, small auxiliary boards and source selection between solar and utility.

Key points

  1. Rated working currents: 10, 16, 20, 25, 32, 40, 50 and 63 A; 2-pole.
  2. Rated working voltage AC 400 V; control voltage AC 230 V; rated insulation voltage AC 500 V; 50/60 Hz.
  3. Rated short-circuit breaking and making capacity 3 kA.
  4. Transfer time ≤ 3 seconds.
  5. ATS class: CB class; standard cited IEC 60947-1.
  6. Protection functions: short circuit, overload, open phase and loss of voltage.
  7. Remote disconnection with a DC 12-24 V interface for the fire protection supply.

Using it in design

  • Calculate the prospective fault current at the installation point; if it exceeds 3 kA, do not use this ATS, or document coordination with a current-limiting upstream device.
  • Because transfer takes up to 3 seconds, use the device only on loads behind a UPS or loads that tolerate a short interruption (lighting, auxiliary circuits).
  • The 2-pole build suits single-phase circuits; show on the earthing diagram that phase and neutral are switched together.
  • Wire the DC 12-24 V remote disconnection input to the fire detection system to design load shedding in a fire scenario.
  • Life, dimensions and environmental data are absent from the page, so request a datasheet and type test report from the manufacturer before board design.

Who should read it

Electrical engineers designing small distribution boards and solar integration, and switchboard designers planning source transfer on auxiliary circuits.

Document contents

  1. Introdução de Produto (Product introduction)
  2. Descrição do produto (Product description)
  3. Technical table: rated current, voltage, short-circuit capacity, transfer time, class, standard

Publication details

Authors
FEEO
Publisher
FEEO
Year
Year not stated
Document language
English
Source type
Manufacturer
Access
Free to read
Licence
Copyright retained; citation only: the publisher’s terms apply to the original document
Original licence note

No document-specific redistribution permission was established. Bibliographic reference only.

Citation

FEEO FEEO 2P Chave de Transferência Automática ATS, technical table. FEEO. https://pt.pv-feeo.com/atuomatic-transfer-switch/2p-automatic-transfer-switch-ats.html

All content and rights belong to the respective authors and publishers. SoSo CAD provides only the citation, its own summary and a link to the source, and is not responsible for the sources' content.

Power design in SoSo CAD

Calculate supply paths, equipment loads and UPS failure scenarios as part of the design.

Single-line diagram in the SoSo CAD power and capacity workspace

Keep your reading list current

Once a month: new library sources, changes to Turkish regulations and upcoming data centre events.