Technical guideFree to readYear not stated

AEC UPS Catalog US 2025 v6-2, Lumina p.8 / Ferrus RT p.16

AEC

The 2025 US UPS catalogue from AEC (Allis Electric) presents product families for the 120 V single-phase market from 1 kVA up to 1200 kVA; the featured Lumina series offers four 2U rack-mount models with internal LiFePO4 batteries (900, 1800, 1980 and 2700 W), a full recharge within two hours and 92% AC/AC efficiency in the technical table.

On this page

Overview

The catalogue gathers the UPS products of the Allis Electric group, founded in Taiwan in 1968, for the US market. The company states that it has commercial and manufacturing locations in Taiwan, Italy, the USA and South Africa and set up its US headquarters in Miami in 2023. The range starts with single-phase 110/120 V series (Lumina, Ferrus, Ferrus RT, each 1 to 3 kVA), continues with the split-phase Ferrus SP series (6 to 20 kVA) and extends to three-phase series such as Etherno and Aureon (10 to 30 kVA) and the modular Radiant (40 to 240 kVA), reaching 1200 kVA at the top.

Lumina is a 2U rack-mount on-line double-conversion UPS with a three-level IGBT inverter and internal lithium iron phosphate (LiFePO4) batteries. Four models are given in separate columns of the technical table: LUM1000RT-2U-LI 900 W, LUM2000RT-2U-LI 1800 W, LUM2200RT-2U-LI 1980 W and LUM3000RT-2U-LI 2700 W, with an output power factor of 0.9. According to the runtime chart, the 1, 2 and 3 kVA models run 12 minutes at full load and 27 minutes at half load, while the 2.2 kVA model runs 23 and 46 minutes. The catalogue gives battery lifespan as 12 to 15 years based on 3000 cycles.

The technical table and the descriptive text differ in places: the description mentions efficiency up to 96% and unity power factor, whereas the table gives 92% AC/AC efficiency and a 0.9 power factor; full-load runtime is 11 and 22 minutes in the description and 12 and 23 in the chart. In the dimension row the height of the 2.2 kVA model in centimetres carries the inch value, and the pound and kilogram figures for the 3 kVA model do not agree. The Ferrus RT series is the rack-mount option with internal batteries in the same power range, extendable with external battery cabinets. The catalogue states that its information is for reference and creates no contractual obligation.

Key points

  1. Lumina models and active power: LUM1000RT-2U-LI 900 W, LUM2000RT-2U-LI 1800 W, LUM2200RT-2U-LI 1980 W, LUM3000RT-2U-LI 2700 W; output power factor 0.9.
  2. Input and output are single-phase 110/120 V; output is set to 100, 110, 115 or 120 V; input frequency 40 to 70 Hz.
  3. Input power factor at least 0.99, input current distortion at most 3%; output voltage distortion at most 1% on linear load and at most 5% on non-linear load.
  4. AC/AC efficiency 92% in the technical table; noise below 50 dB.
  5. Runtime chart: the 1, 2 and 3 kVA models give 12 minutes at 100% load and 27 minutes at 50%; the 2.2 kVA model gives 23 minutes at 100% and 46 minutes at 50%.
  6. Internal LiFePO4 battery: 24, 48 or 72 V DC, 10.6 Ah (13.6 Ah on the 2.2 kVA model); maximum charger current 4 A; 0 to 100% recharge within two hours.
  7. Overload: 102% to 110% for 10 minutes, 111% to 130% for 1 minute, 131% to 150% for 30 seconds.
  8. Certifications: UL 1778, ETL, CSA and UN38.3; standard communications RS232, USB and EPO, with SNMP, Modbus and dry contacts optional.
  9. Other series in the catalogue: Ferrus and Ferrus RT (1 to 3 kVA), Ferrus SP (6 to 20 kVA, split phase), Etherno and Aureon (10 to 30 kVA), Radiant (40 to 240 kVA modular).

Using it in design

  • Size Lumina models from the watt values in the technical table (900 to 2700 W) and the 0.9 power factor; do not rely on the unity power factor wording in the description.
  • Use the tabulated 92% efficiency in heat load calculations.
  • Where edge sites and network cabinets need long backup, compare the 2.2 kVA model's 46 minutes at 1 kW load with VRLA-based alternatives.
  • Ask the manufacturer for a current dimensional drawing for rack depth and weight; the dimension and weight rows in the catalogue contain unit inconsistencies.
  • When placing a lithium-battery UPS in a rack, check local fire code conditions on battery chemistry and the UN38.3 transport document.

Who should read it

Engineers selecting 120 V single-phase rack-mount UPS units in North America, designers of edge sites and network rooms, and teams preparing product catalogue data.

Document contents

  1. AEC History
  2. Our Global Presence and Market Coverage by Region
  3. UPS Online | Series LUMINA (1-3 kVA)
  4. UPS LUMINA Autonomy backup runtime chart
  5. Lithium LiFePO4 technology
  6. Technical specifications
  7. UPS Online | Series FERRUS
  8. UPS Online | Series FERRUS RT
  9. UPS Online | Series FERRUS SP and FERRUS RT SP
  10. UPS Online | Series ETHERNO, AUREON and RADIANT

Publication details

Authors
AEC
Publisher
AEC
Year
Year not stated
Document language
Unverified
Source type
Manufacturer
Access
Free to read
Licence
Copyright retained; citation only: the publisher’s terms apply to the original document
Original licence note

No document-specific redistribution permission was established. Bibliographic reference only.

Citation

AEC AEC UPS Catalog US 2025 v6-2, Lumina p.8 / Ferrus RT p.16. AEC. https://ups.aecups.com/wp-content/uploads/2025/12/AEC_UPS_Catalog_US_2025_v6-2.pdf

All content and rights belong to the respective authors and publishers. SoSo CAD provides only the citation, its own summary and a link to the source, and is not responsible for the sources' content.

Power design in SoSo CAD

Calculate supply paths, equipment loads and UPS failure scenarios as part of the design.

Single-line diagram in the SoSo CAD power and capacity workspace

Keep your reading list current

Once a month: new library sources, changes to Turkish regulations and upcoming data centre events.