İmelsan Enerji İMS 3330 PLUS (30 kVA) product page

İmelsan Enerji

The İMS 3330 PLUS product page of Ankara-based İmelsan Enerji presents a 30 kVA UPS with three-phase input and three-phase output (3x3); the highlighted features are a maintenance bypass, RS232 and a smart-slot interface, and a menu in Turkish and English.

On this page

Overview

The page belongs to the İMS 3330 PLUS model in İmelsan Enerji's uninterruptible power supply range. The heading states the configuration and rating directly: 3x3, meaning three-phase input and three-phase output, at 30 kVA. The manufacturer operates from the Gersan industrial estate in Ergazi, Ankara, and offers regulators, inverters and rectifiers on the same site. Alongside this model the PLUS family includes 3x3 versions at 10 kVA and 20 kVA (ims 3310 PLUS and ims 3320 PLUS) and the 3x1 20 kVA İMS 3120.

The product description is a short list of five features. The manufacturer stresses low installation cost, high reliability and maximum performance. On the hardware side there is a maintenance bypass, which lets the unit be taken out of service without dropping the load. For communication the unit offers an RS232 port and a smart-slot interface, a bay that takes add-ons such as a network monitoring card. The front-panel menu can be set to Turkish or English.

The page gives no active power (kW), output power factor, input or output voltage, efficiency, battery voltage, dimensions or weight. The model is therefore defined in a catalogue by 30 kVA apparent power and the 3x3 configuration, and the remaining data needed for sizing and layout have to come from the manufacturer's technical sheet. Besides Turkish, the page is published in English, Arabic, Spanish, French and German, which shows that the product is also offered to export markets.

Key points

  1. Model: İMS 3330 PLUS; configuration 3x3 (three-phase in, three-phase out); rating 30 kVA.
  2. A maintenance bypass is listed as a standard feature.
  3. Communication: RS232 and a smart-slot interface.
  4. The front-panel menu is available in Turkish and English.
  5. The same family includes 3x3 10 kVA (ims 3310 PLUS), 3x3 20 kVA (ims 3320 PLUS) and 3x1 20 kVA (İMS 3120) models.
  6. The manufacturer, İmelsan Enerji, is located on the Gersan industrial estate in Ergazi, Ankara.

Using it in design

  • Consider the model for small three-phase system-room loads up to 30 kVA, and obtain the kW rating and output power factor from the manufacturer in writing at quotation stage.
  • The maintenance bypass is built in, so clarify with the manufacturer whether an external bypass panel is still needed.
  • Define in the specification the communication card (SNMP or Modbus) to be fitted in the smart slot for connection to the building monitoring system.
  • Take dimensions and weight from the technical sheet for layout and floor loading; the page does not publish them.

Who should read it

Electrical designers and procurement teams evaluating small three-phase UPSs manufactured in Turkey.

Document contents

  1. İMS 3330 PLUS (3X3 30 KVA)
  2. Product features

Publication details

Authors
İmelsan Enerji
Publisher
İmelsan Enerji
Year
Year not stated
Document language
Turkish
Source type
Manufacturer
Access
Free to read
Licence
Copyright retained; citation only: the publisher’s terms apply to the original document
Original licence note

No document-specific redistribution permission was established. Bibliographic reference only.

Citation

İmelsan Enerji İmelsan Enerji İMS 3330 PLUS (30 kVA) product page. İmelsan Enerji. https://www.imelsan.com/tr/urun/ims-3330-plus-3x3-30-kva

All content and rights belong to the respective authors and publishers. SoSo CAD provides only the citation, its own summary and a link to the source, and is not responsible for the sources' content.

Power design in SoSo CAD

Calculate supply paths, equipment loads and UPS failure scenarios as part of the design.

Single-line diagram in the SoSo CAD power and capacity workspace

Keep your reading list current

Once a month: new library sources, changes to Turkish regulations and upcoming data centre events.