İmelsan Enerji İMS DSP 3380 (80 kVA) product page
İmelsan Enerji
The İMS DSP 3380 product page of Ankara-based İmelsan Enerji presents a 80 kVA UPS: efficiency above 93%, built-in static and maintenance bypass, SNMP and Modbus communication, and a 10-year spare-parts guarantee from the manufacturer.
On this page
Overview
The page belongs to the 80 kVA İMS DSP 3380 model in İmelsan Enerji's DSP series, and the rating is printed in the page heading. The manufacturer operates from the Gersan industrial estate in Ergazi, Ankara. The product description is a list of eighteen features with no numerical specification table. The items that concern electrical performance are a high input power factor, low input harmonic distortion (THD) and efficiency above 93%. The efficiency is given as a lower bound, without the load level at which it applies.
For protection and continuity the unit offers static and maintenance bypass, overload and short-circuit protection, an emergency power-off button input and start from battery (cold start). Battery management covers automatic battery test hardware, a remaining-runtime indicator and adjustment of the charging voltage with temperature, a feature aimed at protecting battery life. Event logging is described as a memory of 128 fault states (128 events, 3072 alarms), and there is a calendar, clock and operating-hours display.
Communication options are an RS232 serial port, dry-contact alarm relay outputs, a modem connection for dial-up access, and SNMP and Modbus. Transformer options are offered at the input and output to suit the application. The manufacturer gives a 10-year spare-parts guarantee and states that its services comply with TUV-ISO9002 standards. The page publishes no active power (kW), output power factor, voltage, battery string, dimensions or weight; sizing data for the 80 kVA model has to come from the manufacturer's technical sheet.
Key points
- Model: İMS DSP 3380; rating 80 kVA.
- Efficiency above 93% (given as a lower bound).
- High input power factor and low input harmonic distortion (THD) are declared.
- Static and maintenance bypass, overload and short-circuit protection, emergency power-off button input.
- Start from battery, automatic battery test, remaining-runtime indicator and temperature-dependent charging voltage.
- Event memory: 128 events, 3072 alarms.
- Communication: RS232, dry-contact relay outputs, modem connection, SNMP and Modbus.
- Transformer options at input and output; 10-year spare-parts guarantee.
Using it in design
- Consider the model for loads up to 80 kVA, and obtain the kW rating, output power factor and voltage configuration from the manufacturer in writing at quotation stage.
- Use the 93% efficiency lower bound for heat load: assume losses of up to 7% at full load and request the part-load efficiency curve separately.
- If galvanic isolation or a different voltage is needed, state the input or output transformer option in the specification; a transformer adds weight and size.
- For integration with the building monitoring system, add the SNMP or Modbus interface and the dry-contact alarms to the signal list.
- Where battery-room temperature varies, confirm that the temperature-compensated charging feature is delivered with its sensor.
Who should read it
Electrical designers and procurement teams evaluating medium-power UPSs manufactured in Turkey.
Document contents
- İMS DSP 3380 (80KVA)
- Product features
Publication details
- Authors
- İmelsan Enerji
- Publisher
- İmelsan Enerji
- Year
- Year not stated
- Document language
- Turkish
- Source type
- Manufacturer
- Access
- Free to read
- Licence
- Copyright retained; citation only: the publisher’s terms apply to the original document
Original licence note
No document-specific redistribution permission was established. Bibliographic reference only.
Citation
İmelsan Enerji İmelsan Enerji İMS DSP 3380 (80 kVA) product page. İmelsan Enerji. https://www.imelsan.com/tr/urun/ims-dsp-3380-80kva
All content and rights belong to the respective authors and publishers. SoSo CAD provides only the citation, its own summary and a link to the source, and is not responsible for the sources' content.
