Technical guideFree to readYear not stated

Layer Electronics Futura technical brochure

Original title Layer Electronics Futura technical brochure, PDF pp.3–4

Layer Electronics

Layer Electronics's Futura industrial UPS brochure: VFI class with output isolation transformer, single-phase 5-200 kVA and three-phase 5-1600 kVA ranges, efficiency above 92% and a static switch under 2 ms.

On this page

Overview

Futura is Layer Electronics's industrial UPS series, on the market since 2005 and used in civil and military applications. The brochure describes a DSP-managed design with an output insulation transformer and the ability to run several units in adaptive parallel. Battery charging current is limited when a generating set is running. The series comes in a single-phase version from 5 to 200 kVA (also with three-phase input) and a three-phase version from 5 to 1600 kVA.

The data tables come in three groups: SRE-5/1 to SRE-50/1 (single-phase output, 5-50 kVA), SRE-5 to SRE-80 (three-phase, 5-80 kVA) and SRE-100 to SRE-800 (100-800 kVA). Input voltage is +/-20% and frequency 50/60 Hz +/-5%; output voltage is +/-1%, frequency +/-0.2%, harmonic distortion under 2%, crest factor 3:1 (non-linear load 75%) and overload 125% for 10 minutes, 150% for 1 minute, 200% for 0.1 second. Efficiency is above 92%.

The battery type is sealed lead-acid; NiCd, Li-Ion and NaNiCl2 are available on request. DC voltage is 156, 216, 240 or 384 V depending on model. Restored energy time is 4 hours to 90% charge level. Protections cover overload, overtemperature, battery, input and inverter voltage limits and synchronism; short circuit is electronically protected. Static switch mains-to-UPS transfer is under 2 ms. Classification is VFI to EN 62040-3.

Dimensions run from 800 x 500 x 1100 mm to 5000 x 1500 x 2160 mm and weight from 110 kg to 6000 kg across the steps. Operating temperature is 0-50 C, humidity 0-95% non-condensing, noise under 60 dBA at 1 m and protection IP20. Compliance standards are EN 60146-1-1 and EN IEC 62040-1, -2 and -3, with CE marking under 2014/30/EU, 2014/35/EU and 2011/65/EU. The brochure gives model-level values and no efficiency load-point curve.

Key points

  1. Single-phase version 5-200 kVA (also three-phase input), three-phase version 5-1600 kVA.
  2. Tabulated models: SRE-5/1 to SRE-50/1 (5-50 kVA), SRE-5 to SRE-80, SRE-100 to SRE-800 (100-800 kVA).
  3. Input +/-20%, 50/60 Hz +/-5%; output voltage +/-1%, frequency +/-0.2%.
  4. Output harmonic distortion under 2%; crest factor 3:1 in single- and three-phase.
  5. Overload 125% for 10 min, 150% for 1 min, 200% for 0.1 s; efficiency above 92%.
  6. Static switch mains-UPS transfer under 2 ms; class VFI (EN 62040-3).
  7. Sealed lead-acid battery; DC voltage 156, 216, 240 or 384 V; 90% recharge in 4 hours.
  8. Size 800 x 500 x 1100 mm up to 5000 x 1500 x 2160 mm; weight 110 kg up to 6000 kg.
  9. Operation 0-50 C, IP20, noise under 60 dBA at 1 m.
  10. Output insulation transformer; charge current limited when a generating set runs.

Using it in design

  • Use the VFI class and output insulation transformer as a comparison criterion for industrial loads that need galvanic separation.
  • In generator-fed sites, reflect the charge-current limiting feature in the generator sizing.
  • In the electrical room layout, check the step-dependent dimensions (W x D x H) and the weights from 110 kg to 6000 kg against floor loading.
  • Match the battery DC voltage (156, 216, 240, 384 V) to the battery cabinet and charger design.
  • Take efficiency as above 92% without a stated load point and confirm it with the manufacturer for heat-load calculations.

Who should read it

Electrical designers and specifiers selecting high-power industrial and military-grade UPS.

Document contents

  1. Futura series introduction
  2. Technical data: SRE-5/1 to SRE-50/1
  3. Technical data: SRE-5 to SRE-80
  4. Technical data: SRE-100 to SRE-800

Publication details

Authors
Layer Electronics
Publisher
Layer Electronics
Year
Year not stated
Document language
English
Source type
Manufacturer
Access
Free to read
Licence
Copyright retained; citation only: the publisher’s terms apply to the original document
Original licence note

No document-specific redistribution permission was established. Bibliographic reference only.

Citation

Layer Electronics Layer Electronics Futura technical brochure, PDF pp.3–4. Layer Electronics. https://www.layer.it/main/media/2025/03/Futura-eng.pdf

All content and rights belong to the respective authors and publishers. SoSo CAD provides only the citation, its own summary and a link to the source, and is not responsible for the sources' content.

Power design in SoSo CAD

Calculate supply paths, equipment loads and UPS failure scenarios as part of the design.

Single-line diagram in the SoSo CAD power and capacity workspace

Keep your reading list current

Once a month: new library sources, changes to Turkish regulations and upcoming data centre events.