Bellwin AT1-8B1-15 technical specifications
Bellwin
A Bellwin product page for the AT1-8B1-15: a 1U metered rack PDU with automatic transfer (ATS), 110 VAC input, 15 A maximum, eight NEMA 5-15R outlets and an A/B source transfer time of 8 to 16 ms.
On this page
Overview
The product page from the Taiwanese manufacturer Bellwin Information brings together the ordering options, feature list and specification table of the AT1-8B1-15. The unit has two separate power inlets: when source A develops a fault it moves the load to source B automatically, and it returns to source A once that source recovers. The page gives the transfer time as 8 to 16 ms. Status is shown by LED and a buzzer sounds on overload. The model is intended to give single-corded IT equipment a dual feed inside the rack.
According to the specification table, input voltage is 110 VAC, maximum input current is 15 A and frequency is 50/60 Hz. The input side has two IEC 60320 C20 inlets with separate power cords. The output has eight NEMA 5-15 sockets on a single branch, each limited to 15 A. Standby consumption is 15 W. A three-digit LCD shows the device IP address, voltage and total current, and the current metering error is 1%.
The AT series is the metered type: outlets are not switched individually and the unit monitors the total load. An administrator can follow voltage, current, frequency, power factor, energy (kWh), temperature and humidity remotely through a web browser. Network functions include SNMP v1, v2c and v3, SNMP traps, Syslog, encrypted e-mail and SMS alerts, IP and MAC filtering, event logging and online firmware upgrade. Ethernet speed is 10/100 Mbps. Two COM ports serve terminal and API control and RS232-to-IP conversion. A digital temperature and humidity sensor is optional.
The enclosure is an iron case that mounts in a 19-inch standard rack at 1U; dimensions are 445 x 253 x 44 mm. Operating temperature is 0 to 45 °C, storage temperature 0 to 60 °C, and relative humidity 0 to 90% without condensation. The page gives no weight, and it does not state the type of transfer mechanism, the short-circuit rating or certifications. The product is marked as not available for online sale; a series brochure and an ATS operation manual are offered as separate documents.
Key points
- Input: 110 VAC, 15 A maximum, 50/60 Hz; two IEC 60320 C20 inlets.
- Output: 8 NEMA 5-15 sockets on one branch; 15 A maximum per socket.
- A/B source transfer time 8...16 ms; automatic return when source A recovers.
- Standby consumption 15 W; current metering error 1%; three-digit LCD.
- Dimensions 445 x 253 x 44 mm; 1U in a 19-inch rack; iron case.
- Operating 0...45 °C, storage 0...60 °C; humidity 0...90% non-condensing.
- Management: SNMP v1/v2c/v3, traps, Syslog, e-mail and SMS alerts, IP/MAC filters, 10/100 Mbps Ethernet, 2 COM ports.
- Remotely monitored quantities: voltage, current, frequency, power factor, kWh, temperature and humidity.
Using it in design
- Check total rack load against the 15 A input limit and each device against the 15 A per-socket limit.
- Compare the 8...16 ms transfer time with the power-supply hold-up time of the connected equipment; use the unit for single-corded devices only.
- Connect the two inlets to independent A and B distribution paths; each path must be able to carry the full ATS load.
- Confirm that the socket type (NEMA 5-15) and the 110 VAC input voltage match the site distribution and the equipment cords.
- Reserve 1U of height and 253 mm of depth in the rack plan, and add the 15 W standby consumption to the rack heat load.
Who should read it
Data-centre electrical designers and infrastructure operations teams choosing an in-rack dual-feed solution for single-corded network and IT equipment.
Document contents
- Product options
- Product Features
- Specifications
- Diagram
- DM
- Operation Manual
Publication details
- Authors
- Bellwin
- Publisher
- Bellwin
- Year
- Year not stated
- Document language
- English
- Source type
- Manufacturer
- Access
- Free to read
- Licence
- Copyright retained; citation only: the publisher’s terms apply to the original document
Original licence note
No document-specific redistribution permission was established. Bibliographic reference only.
Citation
Bellwin Bellwin AT1-8B1-15 technical specifications. Bellwin. https://www.bellwin.com.tw/shop/at1-8b1-15-69
All content and rights belong to the respective authors and publishers. SoSo CAD provides only the citation, its own summary and a link to the source, and is not responsible for the sources' content.
