The section of Salzer Electronics' price list effective 25 October 2021 that gives order codes for single-phase and three-phase automatic changeover units with current limiter (ACCL), which distribute generator power without overloading it.

On this page

Overview

The ACCL (Automatic Changeover with Current Limiter) moves the load to generator supply on mains failure and, if the load on the generator exceeds a preset limit, enters an overload trip cycle and alerts users by LED or beep to reduce the excess load. The list presents it for residential apartments, commercial complexes and townships and describes it as a patented design. The rest of the price list covers rotary switches, load break switches, cable ducts, relays, terminals and plugs and sockets; this summary rests on the ACCL pages only.

The single-phase ACCL table gives fifteen discrete order codes with a generator trip (DG Trip) setting and a mains rating of 30 A: 0.5, 1, 1.5, 2.5, 3, 4, 5, 6, 8, 9, 10, 15, 20, 25 and 30 A. Codes run from RACCL005S to RACCL300S. Each row gives the generator trip current and the mains rating in separate columns; the two values are not interchangeable.

For three-phase ACCL there are two configuration tables: TPN-SPN (three-phase mains, single-phase generator) and TPN-TPN. Each has eight codes with DG trip 6, 10, 15, 20, 25, 30, 40 and 63 A, mains 40 A (63 A for the 63 A trip), RACCLTS4006 to RACCLTS6363 and RACCLTT4006 to RACCLTT6363. The three-phase unit has a heavy-duty contactor design with electrical and mechanical interlock.

Two modes are defined for the three-phase unit: in S-mode, if any one phase fails it disconnects from mains and changes over to the generator; in T-mode it changes over if all three phases or the R phase fail. The document is a price list, so technical detail is limited and conditions and unknown fields must stay attached to each configuration.

Key points

  1. Single-phase ACCL: 15 order codes, generator trip 0.5-30 A, mains 30 A (RACCL005S ... RACCL300S).
  2. Single-phase trip values: 0.5, 1, 1.5, 2.5, 3, 4, 5, 6, 8, 9, 10, 15, 20, 25, 30 A.
  3. Three-phase ACCL TPN-SPN: DG trip 6, 10, 15, 20, 25, 30, 40 A with 40 A mains; 63 A with 63 A mains (RACCLTS4006 ... RACCLTS6363).
  4. Three-phase ACCL TPN-TPN: the same current values (RACCLTT4006 ... RACCLTT6363).
  5. If generator load exceeds the limit, the unit enters an overload trip cycle with LED or beep alert.
  6. S-mode: changes over to generator on loss of any phase; T-mode: on loss of all three phases or the R phase.
  7. The three-phase unit has a heavy-duty contactor with electrical and mechanical interlock.
  8. The list is dated 25 October 2021 and carries 18 percent GST; prices are reference product rows.

Using it in design

  • Record generator trip current and mains rating as separate parameters; do not reduce the product to a single current value.
  • For three-phase selection, define the mains and generator phase structure (TPN-SPN or TPN-TPN) and S- or T-mode.
  • The unit is presented for residential and commercial distribution; do not confuse it with STS or ATS products for data-centre critical load transfer.
  • Use the discrete codes in the list; do not derive models for intermediate currents.
  • Confirm price and stock from the current manufacturer source.

Who should read it

Electrical designers and buyers looking at generator load distribution and simple automatic changeover.

Document contents

  1. Contents (price list)
  2. ACCL single phase
  3. ACCL three phase (TPN-SPN, TPN-TPN)

Publication details

Authors
Salzer Electronics
Publisher
Salzer Electronics
Year
2021
Document language
Unverified
Source type
Manufacturer
Access
Free to read
Licence
Copyright retained; citation only: the publisher’s terms apply to the original document
Original licence note

No document-specific redistribution permission was established. Bibliographic reference only.

Citation

Salzer Electronics (2021). Salzer October 2021 Panel Accessories price list: ACCL, printed pp.25–26. Salzer Electronics. https://vishalelectricals.net/images/pricelist/salzer.pdf

All content and rights belong to the respective authors and publishers. SoSo CAD provides only the citation, its own summary and a link to the source, and is not responsible for the sources' content.

Power design in SoSo CAD

Calculate supply paths, equipment loads and UPS failure scenarios as part of the design.

Single-line diagram in the SoSo CAD power and capacity workspace

Keep your reading list current

Once a month: new library sources, changes to Turkish regulations and upcoming data centre events.