SANYO DENKI Product Information: SANUPS S11A Static Transfer Switch

Original title SANYO DENKI Product Information: SANUPS S11A static transfer switch

Sanyo Denki

SANYO DENKI Product Information v6: the SANUPS UPS line runs from 1 kVA to 600 kVA, and the S11A static transfer switch is a 100 VAC single-phase unit rated 30 A with fast switching between sources A and B.

On this page

Overview

The document is a general product information book from Japan's SANYO DENKI covering fans (San Ace), UPS and renewable-energy inverters (SANUPS) and servo systems (SANMOTION). The SANUPS part covers UPS, renewable energy inverters and power supply products; it traces the company's origins to a radio power generator developed in 1927 and notes that redundant configurations keep supply running even if one unit fails.

The UPS line includes on-line UPS models such as the A13A (6.25 to 25 kVA), A22A (5 to 105 kVA), A23D and A23C (30 to 300 kVA) and the parallel-processing E33A (100 to 600 kVA). Battery backup times are 5 to 10 minutes standard and 30 to 180 minutes optional, depending on the model. Networking products include a LAN interface card for remote UPS status management, a network power manager, the C23A voltage dip compensator, the K23A for microgrid management and the K33A peak cut device (maximum output 1800 kW).

The S11A static transfer switch switches the AC input of critical loads between power sources A and B at high speed with a power semiconductor device, and monitors power quality. Input and output are stated as 100 VAC single-phase two-wire, with a rated current of 30 A. The catalogue page introduces the product in a one-line summary; transfer time, detection thresholds and source limits are not given in this document and sit in the product catalogue and instruction manual.

The document is therefore a product map showing where the S11A sits within the SANUPS family and its rated values. European directive and standards compliance vary by model, and the reader is referred to the catalogue and instruction manual for details.

Key points

  1. S11A: 19-inch rack-mountable static transfer switch; high-speed switching with a power semiconductor device and power quality monitoring.
  2. S11A input/output: 100 VAC single-phase two-wire, rated current 30 A; fed from sources A and B.
  3. A22A on-line UPS 5 to 105 kVA, standard backup time 10 min.
  4. A13A 6.25 to 25 kVA (5 to 20 kW), standard backup time 8 min, options 30 and 60 min.
  5. A23D/A23C 30 to 300 kVA (27 to 270 kW), standard 10 min, options 5 to 180 min.
  6. E33A parallel-processing UPS 100 to 600 kVA (90 to 540 kW); 100 to 500 kVA in parallel redundant operation.
  7. C23A voltage dip compensator (10 to 200 kVA) with dip compensation time of 1 s for the 50 to 200 kVA models.
  8. K33A peak cut device has a maximum output capacity of 1800 kW (direct current).

Using it in design

  • Select the 100 VAC, 30 A S11A only for small critical loads on a 100 VAC supply, comparing the rated current with the load total.
  • Verify that sources A and B are in phase and at the same frequency; take operating values such as transfer time from the product catalogue and manual.
  • In dual-source designs, state on the diagram whether the static transfer switch sits before or after the UPS output.
  • Check UPS battery backup time (5 to 10 min standard, 30 to 180 min optional) together with generator start time.
  • When choosing between a voltage dip compensator and a UPS, compare dip duration and harmonic-protection needs.

Who should read it

Electrical designers selecting UPS, static transfer and dual-source supply for the Japanese market or 100 VAC systems.

Document contents

  1. Product overview
  2. SANUPS features
  3. SANUPS lineup: on-line UPS, parallel-processing UPS
  4. Networking products: LAN interface card, network power manager
  5. Voltage dip compensator and grid management
  6. Inverters and static transfer switch (S11A)

Publication details

Authors
Sanyo Denki
Publisher
Sanyo Denki
Year
Year not stated
Document language
English
Source type
Manufacturer
Access
Free to read
Licence
Copyright retained; citation only: the publisher’s terms apply to the original document
Original licence note

No document-specific redistribution permission was established. Bibliographic reference only.

Citation

Sanyo Denki SANYO DENKI Product Information: SANUPS S11A static transfer switch. Sanyo Denki. https://publish.sanyodenki.com/library/books/product_information_E/book/data/product_information_E.pdf

All content and rights belong to the respective authors and publishers. SoSo CAD provides only the citation, its own summary and a link to the source, and is not responsible for the sources' content.

Power design in SoSo CAD

Calculate supply paths, equipment loads and UPS failure scenarios as part of the design.

Single-line diagram in the SoSo CAD power and capacity workspace

Keep your reading list current

Once a month: new library sources, changes to Turkish regulations and upcoming data centre events.