PowerWalker ATS 10120543 official product specifications

PowerWalker

The PowerWalker ATS (SKU 10120543) is a 1U rack 16 A automatic transfer switch: it feeds two independent inputs within 180-258 V AC, transfers in 9-12 ms and supports all VFD, VI and VFI UPS models up to 3000 VA.

On this page

Overview

The page presents BlueWalker's PowerWalker ATS (SKU 10120543). The device is an automatic transfer switch (ATS), also called a static transfer switch (STS). It has two independent power inlets and supplies the load from the primary source. If the primary source fails, the secondary automatically backs up the connected equipment. When power returns to the primary input, the ATS can switch the load back. The preferred source can be selected on the front panel.

Key data are as follows: maximum input current 16 A (within 180-258 V AC) and transfer time of 9 to 12 ms. The manufacturer states that the transfer is seamless to connected equipment. The device can be used with all VFD, VI and VFI model UPS units up to 3000 VA. SNMP Manager and SNMP Manager NG are listed as accessories, and compatible products include many models of the Basic VI, VFD and VFI families.

Physical characteristics: rack form factor, 1U; product dimensions 438 x 330 x 44 mm (D x W x H), product weight 5.0 kg, package 126 x 582 x 393 mm and package weight 5.3 kg. The box contains the ATS, user manual, USB cable, software CD, screws, a C19 input cable, a C14-C13 output cable and a C20-C19 output cable. The EAN is 4260074974959.

The document is a product page. The ATS lets single-input devices be fed from two sources, creating source redundancy for servers and network equipment with a single power cord.

Key points

  1. SKU 10120543; 1U rack automatic transfer switch (ATS/STS).
  2. Two independent inputs; the secondary takes over when the primary is lost, and transfer back is possible once the primary returns.
  3. Maximum input current 16 A, input voltage range 180-258 V AC.
  4. Transfer time 9 to 12 ms.
  5. Preferred source selection on the front panel.
  6. Compatible with all VFD, VI and VFI model UPS units up to 3000 VA.
  7. 438 x 330 x 44 mm (D x W x H); 5.0 kg; SNMP Manager and SNMP Manager NG accessories.
  8. Box contents: ATS, manual, USB cable, software CD, screws, C19 input and C14-C13 and C20-C19 output cables.

Using it in design

  • Use the ATS to share single-cord devices between two separate UPS units or lines, and check the 16 A limit against the total load.
  • Verify that the 9-12 ms transfer time is compatible with the hold-up time of the load power supplies.
  • Set the preferred source on the front panel as the main A line, and make sure both sources share the same phase and earthing arrangement.
  • Add the SNMP Manager accessory to the product scope for monitoring.

Who should read it

Data-centre and network-cabinet designers building source redundancy for single-input IT equipment.

Publication details

Authors
PowerWalker
Publisher
PowerWalker
Year
Year not stated
Document language
Unverified
Source type
Manufacturer
Access
Free to read
Licence
Copyright retained; citation only: the publisher’s terms apply to the original document
Original licence note

No document-specific redistribution permission was established. Bibliographic reference only.

Citation

PowerWalker PowerWalker ATS 10120543 official product specifications. PowerWalker. https://powerwalker.com/product/10120543

All content and rights belong to the respective authors and publishers. SoSo CAD provides only the citation, its own summary and a link to the source, and is not responsible for the sources' content.

Power design in SoSo CAD

Calculate supply paths, equipment loads and UPS failure scenarios as part of the design.

Single-line diagram in the SoSo CAD power and capacity workspace

Keep your reading list current

Once a month: new library sources, changes to Turkish regulations and upcoming data centre events.