OREMA Power

OREMA UNH12-380W: a 100 Ah, 12 V AGM high-rate VRLA battery with a 15-minute discharge capacity of 380 W, 31 kg weight and 10-12-year design life, for UPS and data-centre use.

On this page

Overview

The page presents the UNH12-380W from OREMA's UNH series. The series is 12 V high-rate VRLA batteries designed for UPS systems, data centres and electrical systems, and is based on AGM technology. The manufacturer states that a special corrosion-resistant alloy and thinner plates give a larger plate surface area than ordinary batteries, which allows short, high power pulses. The model is written as 100 Ah, 12 V, with a 15-minute discharge capacity of 380 W at 25 °C.

Physical data: weight 31 kg, 328 x 171 x 214 mm (L x W x H), total height 218 mm. Terminal F11 veya F12. Design life is 10-12 years at 25 °C and warranty is 24 months. Listed certificates are ISO 9001, ISO 14001, ISO 45001, UL, CE and TLC. The carton holds 1 battery. Origin is China; the brand is offered as OREMA or OEM label, with a minimum order of 10 pieces.

The feature list includes a pure lead-calcium grid design, tank-formed plates, plate groups anchored against vibration, low-pressure flame-arresting safety valves, 99 percent internal gas recombination and use in any orientation. The battery is classed as non-spillable and complies with IATA/ICAO provision A67; self-discharge is low and shelf life is six months at 20 °C.

The FAQ explains that a high-rate battery is built for short, high power pulses and that cycle life depends on depth of discharge; keeping discharge near 50 percent gives more useful cycles. The page is a product introduction without a discharge table or full datasheet, so a runtime calculation needs the manufacturer's discharge table separately.

Key points

  1. Model UNH12-380W; 12 V, 100 Ah AGM VRLA battery.
  2. 15-minute discharge capacity 380 W at 25 °C.
  3. Weight 31 kg; 328 x 171 x 214 mm (L x W x H), total height 218 mm.
  4. Terminal F11 veya F12; 1 battery per carton.
  5. Design life 10-12 years at 25 °C; warranty 24 months.
  6. Certificates: ISO 9001, ISO 14001, ISO 45001, UL, CE, TLC.
  7. 99 percent internal gas recombination, any-orientation use, non-spillable class (IATA/ICAO A67).
  8. Minimum order 10 pieces; payment L/C, T/T, D/P, D/A; delivery FOB, CFR, CIF, EXW.

Using it in design

  • Compare the 15-minute W rating with the UPS string's power and runtime requirement; request the discharge table from the manufacturer for longer durations.
  • Include the string weight in rack and floor-loading calculations, multiplying this weight by the number of batteries.
  • Assess design life against ambient temperature; the value applies at 25 °C and falls at higher temperature.
  • Match the terminal type (F11 or F12) with the UPS battery connection kit.

Who should read it

Electrical designers selecting UPS battery strings and teams preparing battery comparison data.

Publication details

Authors
OREMA Power
Publisher
OREMA Power
Year
Year not stated
Document language
Unverified
Source type
Manufacturer
Access
Free to read
Licence
Copyright retained; citation only: the publisher’s terms apply to the original document
Original licence note

No document-specific redistribution permission was established. Bibliographic reference only.

Citation

OREMA Power OREMA UNH high-rate battery: product specifications: UNH / UNH12-380W. OREMA Power. https://www.oremapower.com/high-rate-battery/62828244.html

All content and rights belong to the respective authors and publishers. SoSo CAD provides only the citation, its own summary and a link to the source, and is not responsible for the sources' content.

Power design in SoSo CAD

Calculate supply paths, equipment loads and UPS failure scenarios as part of the design.

Single-line diagram in the SoSo CAD power and capacity workspace

Keep your reading list current

Once a month: new library sources, changes to Turkish regulations and upcoming data centre events.